Dr Reddy's Laboratories Limited – FDA 483, Jan 15, 2019

Record Details

The FDA Form 483 details observations from an inspection, highlighting several deficiencies in quality control and manufacturing processes.

**Key Violations and Observations:**

* **Inadequate Investigations:** * Failure to thoroughly investigate unexplained discrepancies and out-of-specification (OOS) results for stability batches, specifically regarding API impurity levels. * Investigation OOS 310013508 for OOS tablet results was not thorough, failing to confirm the use of tubes as a root cause and not evaluating why a concurrently prepared sample from another lot did not detect the impurity. * Retesting after invalidating OOS results was performed on a single sample rather than the required number per SOP GQA035. * Investigation of complaint 200217023 for a released batch did not extend to other distributed batches of the same product or include analytical testing of returned or reserve samples. * Investigation OOS 310013534 for an OOS tablet assay did not expand to include prior batches, despite hypotheses of analyst error or inappropriate sampling.

* **Data Integrity and Computer Controls:** * Inadequate controls over computer systems to ensure changes to master records are made only by authorized personnel. * Instrument PR186, used for in-process testing, uses a common password, allows operators to change time/date,

Company
Dr Reddy's Laboratories Limited
Inspection date
January 15, 2019
Product type
drugs
Office
Office of Biological Products Operations - Division I
People
  • Rumany C. Penn (Compliance Officer)
  • Justin A. Boyd (Research Specialist II)
View Company Profile

ID · 2e7927af-43da-467b-a233-11f994f3be46

Violation Codes5
FD&C Act 801(a)(3)21 CFR 331(c)21 CFR 21021 CFR 21121 U.S.C. 324(a)(4)

Full citation text and observation details available on the Dashboard.

Other documents for Dr Reddy's Laboratories Limited
  • 483 - 2025-12-12December 12, 2025
  • 483 - 2024-08-23August 23, 2024
  • 483 - 2017-06-16June 16, 2017

Your cart

Your cart is empty.

Browse public document pages and click Buy this document. We'll ask for your email at checkout, no account needed up front.

Browse documents

Discuss this record with AI

KeyPedia

ChatGPT

Claude

Perplexity

Grok

Copilot

Document or profile

One record shows the event. A profile shows the pattern.

Buy this document for the source file and details behind this single event.

Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.

Explore Dr Reddy's Laboratories Limited
KeyPedia
Regulatory Data Transformed
Stay in the loop

KRA score changes, company updates and news. About monthly, unsubscribe anytime.

Contact
New York Office:
370 Jay Street 7th Floor
Brooklyn, NY 11201
Scranton Office:
Scranton Enterprise Center, Suite 217
201 Lackawanna Avenue
Scranton, PA, 18503
🇺🇸+1 917-789-5099
🇪🇺+48 532-447-507
info@keypedia.com
Quick Links
HomePlatform OverviewMedia
KeyPedia™ Lite
Browse HubDatabase DirectoryRecordsCompaniesOfficesPeopleCareersAbout UsFounding TeamMeet Our ExpertsPartners
Legal & Ethics
Privacy PolicyTerms of ServiceOur Values & MissionCode of Ethics & AI Policy
©2026 KeyPedia™ | Global Key Solutions Corp. All rights reserved.