FDA 483 - Lupin Manufacturing Solutions Limited - January 17, 2020
Discuss this record with AI
This FDA Form 483 document details observations from an inspection, highlighting deficiencies in critical process parameter control, discrepancy investigations, secondary reference standard management, and raw material sampling.
**Facility and Operation Details:** The document refers to the production of intermediates and Active Pharmaceutical Ingredients (API), including exhibit batches and process performance qualification (PPQ) studies.
**Violations and Observations:**
* **Process Validation Deficiencies:** * Failure to identify critical process parameters (CPPs) during PPQ studies. For example, "Quantity of" was identified as a CPP, while other parameters crucial for chemical reactions were deemed non-critical in PPQ protocols/reports (PVP/MPP1/065/00, PVR/MPP1/063/00, PVR/MPP1/068/00). * Failure to perform hold time studies during critical processes and production steps. Hold time studies were only conducted after all chemical reactions were complete. * **Discrepancy Investigation Failure:** The firm failed to thoroughly review unexplained discrepancies, even for distributed batches. Specifically, during exhibit batch production and PPQ studies, discrepancies were not investigated in a timely manner. Instead, a change control was initiated to revise product limits for API (e.g., exhibit batch results for batch #, batch #, and batch # showed varying results). * **Secondary Reference Standard Deficiencies:**
- Inspection Date
- January 17, 2020
ID · a9b30d56-7ebd-41de-8ce5-2a10a5805359
Full citation text and observation details available on the Dashboard.