Record Details

**FDA 483 Summary for Medtronic Puerto Rico Operations Co.**

**Inspection Dates:** April 5, 2016 - April 28, 2016 **Location:** Juncos, PR **Establishment Type:** Medical Device Manufacturer **FEI Number:** 3004639318 **Report Issued to:** Mr. Felix M. Negron, Vice President of Operations

**Main Violations/Issues:**

1. **Process Monitoring and Control:** The firm failed to establish adequate procedures for monitoring and controlling process parameters for validated processes. Specifically, the performance qualification reports for the sealing processes of implantable devices, such as Synchromed II infusion pumps, did not include necessary product testing to ensure continued compliance with device specifications.

2. **Acceptance Procedures:** The procedures for accepting in-process products were inadequate. The acceptance activities did not fully represent the device's functionality or operational range, particularly for Paradigm Insulin Infusion Pumps, resulting in potential non-compliance with critical product specifications.

3. **Corrective and Preventive Actions (CAPA):** The documentation of CAPA activities was insufficient. The firm did not adequately document the evaluation of reported problems or the implementation of corrective actions to address these issues.

**Regulatory Framework:** The observations are based on the FDA's quality system requirements, which mandate that manufacturers conduct internal audits to identify and correct violations.

**Required Actions:** Medtronic Puerto Rico Operations Co. must address the noted deficiencies by establishing comprehensive procedures for process validation, enhancing acceptance testing protocols, and ensuring thorough documentation of CAPA activities. The firm is responsible for conducting internal audits to rectify all quality system violations and may discuss corrective actions with FDA representatives.

**Contact Information:** For further inquiries or to submit corrective action plans, contact the FDA at the provided address and phone number.

Company
Medtronic Puerto Rico Operations Co.
Inspection date
April 28, 2016
Product type
Device
Office
San Juan District Office
Person
  • Laiza V. Garcia (investigator)
View Company Profile

ID · e7963ab0-99a2-4880-8a11-187c31cde1d2

Your cart

Your cart is empty.

Browse public document pages and click Buy this document. We'll ask for your email at checkout, no account needed up front.

Browse documents

Discuss this record with AI

KeyPedia

ChatGPT

Claude

Perplexity

Grok

Copilot

Document or profile

One record shows the event. A profile shows the pattern.

Buy this document for the source file and details behind this single event.

Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.

Explore Medtronic Puerto Rico Operations Co.
KeyPedia
Regulatory Data Transformed
Stay in the loop

KRA score changes, company updates and news. About monthly, unsubscribe anytime.

Contact
New York Office:
370 Jay Street 7th Floor
Brooklyn, NY 11201
Scranton Office:
Scranton Enterprise Center, Suite 217
201 Lackawanna Avenue
Scranton, PA, 18503
🇺🇸+1 917-789-5099
🇪🇺+48 532-447-507
info@keypedia.com
Quick Links
HomePlatform OverviewMedia
KeyPedia™ Lite
Browse HubDatabase DirectoryRecordsCompaniesOfficesPeopleCareersAbout UsFounding TeamMeet Our ExpertsPartners
Legal & Ethics
Privacy PolicyTerms of ServiceOur Values & MissionCode of Ethics & AI Policy
©2026 KeyPedia™ | Global Key Solutions Corp. All rights reserved.