2UD/DEV ,QFRUSRUDWHG – FDA EIR, May 28, 2019

Record Details

A routine surveillance inspection of OraLabs, Incorporated, a medical device manufacturer in Parker, CO, was conducted by the FDA from May 23 to May 28, 2019. The inspection focused on the firm's Quality System, specifically Corrective and Preventive Actions (CAPA), Design Controls, and Production and Process Controls, using the OraLabs Oral-B Nighttime Dental Guard as the review product. The inspection revealed two primary deficiencies. First, OraLabs had not established formal procedures for design control or design change control, as required by 21 CFR 820.30. The existing Design History File for their dental guard also failed to demonstrate compliance, lacking crucial elements such as risk analysis, design verification, validation, and design review. Second, the company's written Medical Device Reporting (MDR) procedures were inadequate, failing to meet requirements under 21 CFR 803.17. Specific issues included the absence of definitions for adverse events and MDR, clear timeframes for reporting, a standardized review process for determining reportability, and a mandate to evaluate all complaints for potential reportability. Additionally, during the inspection closeout, it was noted that the firm's Product Recall Procedure lacked several key regulatory requirements outlined in 21 CFR Part 806, concerning the reporting of reportable recall initiations to the FDA, specific notification timeframes (within 10 working days), and the required content for such reports, including expansions to existing recalls. Mr. Gary H. Schlatter, President/CEO, acknowledged these observations and committed to correcting them, promising a written response to the FDA within fifteen working days. Management was also cautioned about potential enforcement actions for unaddressed deficiencies.

Company
2UD/DEV ,QFRUSRUDWHG
Inspection date
May 28, 2019
Product type
devices
Office
Denver District Office
Person
  • Matthew M. Vernon (investigator)
View Company Profile

ID · 6b1e900e-ea54-4660-8e6e-82b342c5e7f6

Violation Codes10
21 CFR 82021 CFR 820.30(e)21 CFR 820.30(j)21 CFR 820.3(k)21 CFR 820.19821 CFR 803.1721 CFR 803.17(a)21 CFR 803.17(b)21 CFR 806.10(a)21 CFR 806.10(b)

Full citation text and observation details available on the Dashboard.

Your cart

Your cart is empty.

Browse public document pages and click Buy this document. We'll ask for your email at checkout, no account needed up front.

Browse documents

Discuss this record with AI

KeyPedia

ChatGPT

Claude

Perplexity

Grok

Copilot

Document or profile

One record shows the event. A profile shows the pattern.

Buy this document for the source file and details behind this single event.

Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.

Explore 2UD/DEV ,QFRUSRUDWHG
KeyPedia
Regulatory Data Transformed
Stay in the loop

KRA score changes, company updates and news. About monthly, unsubscribe anytime.

Contact
New York Office:
370 Jay Street 7th Floor
Brooklyn, NY 11201
Scranton Office:
Scranton Enterprise Center, Suite 217
201 Lackawanna Avenue
Scranton, PA, 18503
🇺🇸+1 917-789-5099
🇪🇺+48 532-447-507
info@keypedia.com
Quick Links
HomePlatform OverviewMedia
KeyPedia™ Lite
Browse HubDatabase DirectoryRecordsCompaniesOfficesPeopleCareersAbout UsFounding TeamMeet Our ExpertsPartners
Legal & Ethics
Privacy PolicyTerms of ServiceOur Values & MissionCode of Ethics & AI Policy
©2026 KeyPedia™ | Global Key Solutions Corp. All rights reserved.