•Greiner Bio-One GmbH•October 25, 2018

Greiner Bio-One GmbH – FDA EIR, Oct 25, 2018

Record Details

An FDA "For Cause" inspection of Greiner Bio-One GmbH, a medical device manufacturer based in Kremsmuenster, Austria, was conducted from October 22-25, 2018. The inspection, carried out under CP7382.845 for Medical Device Manufacturers, focused on the firm's Class 2 Vacuette K2 EDTA blood collection tubes, which are regulated by the FDA under the FD&C Act. The inspection identified significant deficiencies, leading to the issuance of an FDA Form 483, Inspectional Observations. Key issues included inadequate design controls, particularly concerning software validation. Procedures for radiation sterilization were found to be deficient, specifically the failure to identify a representative product for a product family, violating ISO Standard 11137-2 and 21 CFR 820.75(a). Furthermore, the firm's corrective and preventive action (CAPA) system was inadequately established, with shortcomings in identifying root causes, ensuring effectiveness of corrective actions, and proper documentation. Concerns were also raised regarding the lack of rationale for 510(k) submissions for design and material changes, which could impact device safety and effectiveness. Greiner Bio-One GmbH management acknowledged the observations and committed to submitting a written response outlining corrective actions within 15 business days. The FDA emphasized that these deficiencies could lead to regulatory actions such as a Warning Letter or import detention if not adequately addressed. The firm subsequently submitted a response with proposed corrective actions, which will require review during a future inspection to confirm effective implementation.

Company
Greiner Bio-One GmbH
Inspection date
October 25, 2018
Product type
devices
Office
Center for Devices and Radiological Health
People
  • Matthew A. Humbard (investigator)
  • Harald Gruellenberger (recipient)
  • Melanie W. Pishnery
View Company Profile

ID · 90b25a3a-fff4-412d-ab0f-b5d2b7572162

Violation Codes5
21 CFR 820.19821 CFR 820.3021 CFR 820.10021 CFR 80321 CFR 820.75(a)

Full citation text and observation details available on the Dashboard.

Other documents for Greiner Bio-One GmbH
  • 483 - 2018-10-25October 25, 2018

Your cart

Your cart is empty.

Browse public document pages and click Buy this document. We'll ask for your email at checkout, no account needed up front.

Browse documents

Discuss this record with AI

KeyPedia

ChatGPT

Claude

Perplexity

Grok

Copilot

Document or profile

One record shows the event. A profile shows the pattern.

Buy this document for the source file and details behind this single event.

Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.

Explore Greiner Bio-One GmbH
KeyPedia
Regulatory Data Transformed
Stay in the loop

KRA score changes, company updates and news. About monthly, unsubscribe anytime.

Contact
New York Office:
370 Jay Street 7th Floor
Brooklyn, NY 11201
Scranton Office:
Scranton Enterprise Center, Suite 217
201 Lackawanna Avenue
Scranton, PA, 18503
🇺🇸+1 917-789-5099
🇪🇺+48 532-447-507
info@keypedia.com
Quick Links
HomePlatform OverviewMedia
KeyPedia™ Lite
Browse HubDatabase DirectoryRecordsCompaniesOfficesPeopleCareersAbout UsFounding TeamMeet Our ExpertsPartners
Legal & Ethics
Privacy PolicyTerms of ServiceOur Values & MissionCode of Ethics & AI Policy
©2026 KeyPedia™ | Global Key Solutions Corp. All rights reserved.