•Greiner Bio-One North America, Inc.•December 13, 2019

Greiner Bio-One North America, Inc. – FDA EIR, Dec 13, 2019

Record Details

An FDA inspection of Greiner Bio-One North America, Inc., a medical device manufacturer in Monroe, NC, was conducted from December 9-13, 2019. This follow-up inspection, under the regulatory framework for medical device manufacturers (21 CFR Part 820, Quality System Regulation), identified nine significant deficiencies, with some being repeat observations from a 2017 inspection. Key violations included the failure to complete validation testing for a new raw material supplier before product release and inadequate complaint handling, specifically not recording all device failures and failing to submit Medical Device Reports (MDRs) for serious incidents. The inspection also found issues with process validation, such as using uncalibrated injection molding machines and lacking validation for recycled resin. Furthermore, procedures for corrective and preventive actions (CAPA) were deemed ineffective, finished device acceptance tests did not conform to ISO standards, and equipment calibration schedules were not followed. Deficiencies in the quality agreement with the parent company and undocumented rationales for sampling plans were also cited. At the inspection's close, the company received a nine-item FDA-483, Inspectional Observations. Management committed to correcting all observations and was reminded of their responsibility to comply with the Federal Food, Drug, and Cosmetic Act to avoid potential enforcement actions.

Company
Greiner Bio-One North America, Inc.
Inspection date
December 13, 2019
Product type
devices
Office
Atlanta District Office
People
  • David E. Lowe (issuing_officer)
  • Edward E. Lockwood
  • Matthew A. Humbard (investigator)
View Company Profile

ID · 76af0a51-5c4c-4106-a6a4-2e23df012fc3

Violation Codes10
21 CFR 820.80(d)21 CFR 820.30(a)21 CFR 820.19821 CFR 820.3021 CFR 820.250(b)21 CFR 820.100(a)21 CFR 820.50(a)(2)21 CFR 82021 CFR 820.10021 CFR 820.70(a)

Full citation text and observation details available on the Dashboard.

Other documents for Greiner Bio-One North America, Inc.
  • 483 - 2021-10-29October 29, 2021
  • EIR - 2021-10-29October 29, 2021
  • 483 - 2019-12-13December 13, 2019
  • WARNING_LETTER - 2019-12-13December 13, 2019

Your cart

Your cart is empty.

Browse public document pages and click Buy this document. We'll ask for your email at checkout, no account needed up front.

Browse documents

Discuss this record with AI

KeyPedia

ChatGPT

Claude

Perplexity

Grok

Copilot

Document or profile

One record shows the event. A profile shows the pattern.

Buy this document for the source file and details behind this single event.

Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.

Explore Greiner Bio-One North America, Inc.
KeyPedia
Regulatory Data Transformed
Stay in the loop

KRA score changes, company updates and news. About monthly, unsubscribe anytime.

Contact
New York Office:
370 Jay Street 7th Floor
Brooklyn, NY 11201
Scranton Office:
Scranton Enterprise Center, Suite 217
201 Lackawanna Avenue
Scranton, PA, 18503
🇺🇸+1 917-789-5099
🇪🇺+48 532-447-507
info@keypedia.com
Quick Links
HomePlatform OverviewMedia
KeyPedia™ Lite
Browse HubDatabase DirectoryRecordsCompaniesOfficesPeopleCareersAbout UsFounding TeamMeet Our ExpertsPartners
Legal & Ethics
Privacy PolicyTerms of ServiceOur Values & MissionCode of Ethics & AI Policy
©2026 KeyPedia™ | Global Key Solutions Corp. All rights reserved.