Record Details

An FDA inspection of Medtronic MiniMed Inc., located in Northridge, CA, took place from July 5 to July 22, 2016. This high-priority inspection was a directed Investigational Device Exemption (IDE) review, focusing on a study for the Enlite 3 glucose sensor and associated transmitters, conducted under the regulatory guidance of 21 CFR Part 812. The main issue identified during the inspection, leading to a single observation on Form FDA-483, was inaccurate and incomplete records regarding device disposition. Specifically, investigational GST4C transmitters with an older software version (1.0A) were inadvertently used at clinical site 004 for three subjects, despite the study protocol requiring a newer software version (1.1A). Medtronic MiniMed did not detect this discrepancy during the clinical trial or prior to submitting the clinical data to the FDA, only discovering it on July 7, 2016, during the inspection. Although an internal impact assessment concluded that the software difference did not affect sensor data, the firm's failure to maintain accurate device accountability constituted a violation of 21 CFR 812.140(b)(2). Medtronic MiniMed management acknowledged the finding and committed to submitting a written response outlining their corrective actions to the Los Angeles District Office within 15 working days.

Company
Medtronic MiniMed, Inc.
Inspection date
July 22, 2016
Product type
devices
Office
Center for Devices and Radiological Health
People
  • Hooman Kakami (company_representative)
  • Julie Brooke (company_representative)
  • Scott Lee (company_representative)
  • Francine R. Kaufman (Vice President)
  • John J. Shin (company_representative)
View Company Profile

ID · 22d25823-3330-4fe7-9644-5a4d8ccf5fe5

Violation Codes5
21 CFR 81221 CFR 5821 CFR 812.43(c)21 CFR 31221 CFR 812.140(b)(2)

Full citation text and observation details available on the Dashboard.

Other documents for Medtronic MiniMed, Inc.
  • EIR - 2023-03-10March 10, 2023
  • 483 - 2023-03-10March 10, 2023
  • 483 - 2021-07-07July 7, 2021
  • EIR - 2019-02-15February 15, 2019
  • 483 - 2018-03-14March 14, 2018

Your cart

Your cart is empty.

Browse public document pages and click Buy this document. We'll ask for your email at checkout, no account needed up front.

Browse documents

Discuss this record with AI

KeyPedia

ChatGPT

Claude

Perplexity

Grok

Copilot

Document or profile

One record shows the event. A profile shows the pattern.

Buy this document for the source file and details behind this single event.

Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.

Explore Medtronic MiniMed, Inc.
KeyPedia
Regulatory Data Transformed
Stay in the loop

KRA score changes, company updates and news. About monthly, unsubscribe anytime.

Contact
New York Office:
370 Jay Street 7th Floor
Brooklyn, NY 11201
Scranton Office:
Scranton Enterprise Center, Suite 217
201 Lackawanna Avenue
Scranton, PA, 18503
🇺🇸+1 917-789-5099
🇪🇺+48 532-447-507
info@keypedia.com
Quick Links
HomePlatform OverviewMedia
KeyPedia™ Lite
Browse HubDatabase DirectoryRecordsCompaniesOfficesPeopleCareersAbout UsFounding TeamMeet Our ExpertsPartners
Legal & Ethics
Privacy PolicyTerms of ServiceOur Values & MissionCode of Ethics & AI Policy
©2026 KeyPedia™ | Global Key Solutions Corp. All rights reserved.