Record Details

An FDA inspection of Orthodent Laboratory, Inc. was conducted from March 22-24, 2021, as part of the FY21 medical device workplan, adhering to CP 7382.845 for medical device manufacturers. The inspection revealed ten significant observations, primarily concerning the firm's quality system and manufacturing processes for Vivid Aligners (Class II). Major issues identified included the absence of a complete device master record and approved specifications for the aligners, and the lack of validation for the 3D printing process and its operating software. Device history records were found to be incomplete, failing to fully document manufacturing compliance.

Further deficiencies included inadequate supplier evaluation and monitoring, and insufficient identification and documentation of product acceptance status. The corrective and preventive action (CAPA) procedures were deemed inadequate, lacking verification of effectiveness and documented investigations. Controls for nonconforming products and rework processes were also not properly established or documented. Additionally, equipment maintenance and calibration schedules were not adequately maintained, personnel training records were missing, and document control procedures lacked proper approval signatures and dates for internal documents. Management accepted all observations and committed to submitting a written response to the FDA with planned corrections and timelines.

Company
Orthodent Laboratory, Inc.
Inspection date
March 24, 2021
Product type
Devices
Office
Department of Health and Human Services
People
  • Brendan M. Pratt (company_representative)
  • Michael A. Wright (recipient)
  • Matthew D. Schnittker
View Company Profile

ID · c4f1684d-f2dd-470c-b8ff-e40b98b36f6c

Violation Codes10
21 CFR 820.19821 CFR 820.25(b)21 CFR 820.100(a)21 CFR 820.8621 CFR 820.70(g)(2)21 CFR 82021 CFR 820.10021 CFR 820.90(a)21 CFR 820.75(a)21 CFR 820.50

Full citation text and observation details available on the Dashboard.

Other documents for Orthodent Laboratory, Inc.
  • 483 - 2023-11-13November 13, 2023
  • 483 - 2021-03-24March 24, 2021

Your cart

Your cart is empty.

Browse public document pages and click Buy this document. We'll ask for your email at checkout, no account needed up front.

Browse documents

Discuss this record with AI

KeyPedia

ChatGPT

Claude

Perplexity

Grok

Copilot

Document or profile

One record shows the event. A profile shows the pattern.

Buy this document for the source file and details behind this single event.

Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.

Explore Orthodent Laboratory, Inc.
KeyPedia
Regulatory Data Transformed
Stay in the loop

KRA score changes, company updates and news. About monthly, unsubscribe anytime.

Contact
New York Office:
370 Jay Street 7th Floor
Brooklyn, NY 11201
Scranton Office:
Scranton Enterprise Center, Suite 217
201 Lackawanna Avenue
Scranton, PA, 18503
🇺🇸+1 917-789-5099
🇪🇺+48 532-447-507
info@keypedia.com
Quick Links
HomePlatform OverviewMedia
KeyPedia™ Lite
Browse HubDatabase DirectoryRecordsCompaniesOfficesPeopleCareersAbout UsFounding TeamMeet Our ExpertsPartners
Legal & Ethics
Privacy PolicyTerms of ServiceOur Values & MissionCode of Ethics & AI Policy
©2026 KeyPedia™ | Global Key Solutions Corp. All rights reserved.