Attention www.globalkeysolutions.net is now www.keypedia.com, read the full press release here.
KeyPedia LogoKeyPedia Icon
  1. Home
  2. /
  3. Records
  4. /
  5. Eir
  6. /
EIR
••September 18, 2009

FDA EIR - Unknown Company - September 18, 2009

View on Dashboard

Your cart

Your cart is empty.

Browse public document pages and click Buy this document. We'll ask for your email at checkout, no account needed up front.

Browse documents

Discuss this record with AI

ChatGPT

Claude

Perplexity

Grok

Copilot

Document or profile

One record shows the event. A profile shows the pattern.

Buy this document for the source file and details behind this single event.

Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.

Explore this company
Record Details

New Era Foods, LLC underwent an FDA compliance follow-up inspection from September 14-18, 2009, as a low-acid canned food manufacturer. This inspection followed a critical period for the company. A previous FDA inspection (late 2007-early 2008) identified severe Good Manufacturing Practice (GMP) and Low Acid Canned Food (LACF) deficiencies. Key issues included failures in managing process deviations, inadequate evaluation of defective product lots, absence of temperature distribution studies for retort systems, and the alarming detection of Clostridium botulinum spores in finished product and cooling water. Other significant problems involved unqualified can seam teardowns resulting in loose seams, improper cooling water treatment, and inadequate retort traffic control, leading to commingling of cooked and uncooked products. These violations led to an FDA 483, multiple voluntary recalls, state product seizure, and the imposition of an Emergency Permit, prohibiting interstate commerce. During the 2009 follow-up, the firm, under new ownership and management, had notably addressed all prior FDA 483 observations and discussion points, with significant capital improvements to processing and water systems. No new FDA 483 was issued. The inspection confirmed that critical processing factors and container integrity were met for current operations. However, an unprotected underground suction potential in the water supply remained a discussion item, which management committed to rectifying. The company continues to operate under its Emergency Permit.

Inspection Date
September 18, 2009
Product Type
Other
Office
FDA District Office — Not available in document, Not available in document
People
  • Cheryl McClure (company_representative)
  • Kelley L. Clark
  • Joel Smith (company_representative)
  • Robert G. Taylor (investigator)
  • Anthony Petriella (investigator)
Open in Dashboard

ID · e0bb0261-6c35-472e-89b1-6d7c6870781a

Violation Codes8
FD&C Act 41421.U.S.C. 355(a)21 CFR 21121 CFR 108.35(c)(2)(ii)21 CFR 113.8121 CFR 113.81(e)21 CFR 113.81(f)21 CFR 113.83

Full citation text and observation details available on the Dashboard.

KeyPedia
Regulatory Data Transformed
Contact
New York Office:
370 Jay Street 7th Floor
Brooklyn, NY 11201
Scranton Office:
Scranton Enterprise Center, Suite 217
201 Lackawanna Avenue
Scranton, PA, 18503
🇺🇸+1 917-789-5099
🇪🇺+48 532-447-507
info@globalkeysolutions.net
Quick Links
HomePlatform OverviewMedia
KeyPedia™ Lite
Browse HubDatabase DirectoryRecordsCompaniesOfficesPeopleCareersAbout UsFounding TeamMeet Our ExpertsPartners
Legal & Ethics
Privacy PolicyTerms of ServiceOur Values & MissionCode of Ethics & AI Policy
©2026 KeyPedia™ | Global Key Solutions Corp. All rights reserved.