FDA WARNING_LETTER - Osteolife Biomedical I LLC - February 04, 2022
Discuss this record with AI
Document or profile
One record shows the event. A profile shows the pattern.
Buy this document for the source file and details behind this single event.
Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.
The FDA issued a Warning Letter to OsteoLife Biomedical I LLC following an inspection from December 6, 2021, to February 4, 2022, which revealed significant deviations from 21 CFR Part 1271 for human cells, tissues, and cellular and tissue-based products (HCT/Ps).
Key violations include: 1. **Failure to prevent contamination (21 CFR 1271.220(a))**: Multiple batches of Freeze-Dried Particulate Bone from single donors were processed on the same day with the same equipment and technician without cleaning between batches. Post-processing cultures repeatedly tested positive for microorganisms (e.g., Bacillus, Stenotrophomonas maltophilia, Pseudomonas aeruginosa, Micrococcus luteus), yet other batches from the same donor were distributed. Additionally, a sterile sheet covered the laminar flow bench's return air slots during processing, increasing contamination risk. 2. **Failure to validate processes (21 CFR 1271.230(a))**: The manufacturing processes for Flexo-Plate, Flexo-Membrane, and Freeze-Dried Particulate Bone products were not adequately validated. Validation reports lacked in-process microbiological testing and acceptance criteria for contamination. 3. **Failure to monitor environmental conditions (21 CFR 1271.195(c))**: Environmental monitoring for microorganisms was conducted approximately quarterly and not
ID · 24458929-f02e-481c-af69-9cb14309ebbb
Full citation text and observation details available on the Dashboard.