Attention www.globalkeysolutions.net is now www.keypedia.com, read the full press release here.
KeyPedia LogoKeyPedia Icon
  1. Home
  2. /
  3. Records
  4. /
  5. Warning Letter
  6. /
  7. Siemens Healthcare Diagnostics, Inc.
WARNING LETTER
•Siemens Healthcare Diagnostics, Inc.•January 4, 2012

Siemens Healthcare Diagnostics, Inc. – FDA Warning Letter, Jan 4, 2012

Record Details

The FDA issued a Warning Letter to Siemens Healthcare Diagnostics, Inc. following a 2011-2012 inspection of their East Walpole, MA facility. The inspection found their in vitro diagnostic devices, including iPTH, adulterated due to non-conformity with Quality System (QS) regulation (21 CFR Part 820). The firm's FDA 483 response was not reviewed due to late submission. Key QS violations included inadequate procedures for device design validation and verification (21 CFR 820.30(g), 820.30(f)), process validation (21 CFR 820.75(a)), and corrective and preventive actions (CAPA) (21 CFR 820.100(a)). The firm also failed to adequately document CAPA activities (21 CFR 820.100(b)), establish proper complaint handling procedures (21 CFR 820.198(a)), and investigate complaints thoroughly (21 CFR 820.198(c)). Further deficiencies involved inadequate product identification (21 CFR 820.60) and device history records (21 CFR 820.184). Additionally, devices were misbranded due to Medical Device Reporting (MDR) failures (21 CFR Part 803), specifically not submitting 15 malfunction reports within 30 days (21 CFR 803.50(a)(2)) and failing to submit supplemental information (21 CFR 803.56). Violations under 21 CFR Part 806 included not reporting device corrections or removals (21 CFR 806.10(a)(1)) and inadequate documentation for not reporting such actions (21 CFR 806.20(b)(4)). The FDA requires prompt correction. Non-compliance may lead to regulatory actions like seizure, injunction, civil money penalties, and impact on federal contracts and device approvals. A written response detailing corrective and preventive actions, with a timetable, is required within fifteen business days. The firm is responsible for ensuring overall compliance.

Company
Siemens Healthcare Diagnostics, Inc.
Inspection date
January 4, 2012
Product type
Devices
Office
New England District Office
View Company Profile

ID · 80d95e7d-e09b-46a9-93bd-accf243d235f

Violation Codes1
21 CFR 806.20(b)(4)

Full citation text and observation details available on the Dashboard.

Other documents for Siemens Healthcare Diagnostics, Inc.
  • WARNING_LETTER - 2012-02-09February 9, 2012

Your cart

Your cart is empty.

Browse public document pages and click Buy this document. We'll ask for your email at checkout, no account needed up front.

Browse documents

Discuss this record with AI

KeyPedia

ChatGPT

Claude

Perplexity

Grok

Copilot

Document or profile

One record shows the event. A profile shows the pattern.

Buy this document for the source file and details behind this single event.

Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.

Explore Siemens Healthcare Diagnostics, Inc.
KeyPedia
Regulatory Data Transformed
Stay in the loop

KRA score changes, company updates and news. About monthly, unsubscribe anytime.

Contact
New York Office:
370 Jay Street 7th Floor
Brooklyn, NY 11201
Scranton Office:
Scranton Enterprise Center, Suite 217
201 Lackawanna Avenue
Scranton, PA, 18503
🇺🇸+1 917-789-5099
🇪🇺+48 532-447-507
info@keypedia.com
Quick Links
HomePlatform OverviewMedia
KeyPedia™ Lite
Browse HubDatabase DirectoryRecordsCompaniesOfficesPeopleCareersAbout UsFounding TeamMeet Our ExpertsPartners
Legal & Ethics
Privacy PolicyTerms of ServiceOur Values & MissionCode of Ethics & AI Policy
©2026 KeyPedia™ | Global Key Solutions Corp. All rights reserved.