FDA 483 - American Natl. Red Cross-Greater Chesapeake & Potomac Region - June 23, 2008
Discuss this record with AI
Document or profile
One record shows the event. A profile shows the pattern.
Buy this document for the source file and details behind this single event.
Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.
The FDA Form 483 details multiple significant deficiencies at the Greater Chesapeake and Potomac Region facility.
**Facility and Operation Details:** The facility is involved in the collection, processing, and distribution of whole blood and blood components, including leukoreduced red blood cells and platelet products.
**Violations and Observations:**
1. **Overweight Whole Blood Units:** The region failed to identify, investigate, correct, and trend 197 instances of overweight whole blood units collected between November 2006 and May 2008. This violates step 3 of a redacted SOP requiring deviation logging, tracking, and trending. This issue was previously cited in April-June 2002 and September-January 2006 FDA inspections, indicating ineffective corrective actions. 2. **Inadequate Manufacturing Record Reviews and Non-Conforming Products:** * **Irradiated RBCs without Second Party Review:** On 12/31/07, 10 leukoreduced red blood cells were distributed on 11/22/07 without required second-party review of the irradiation batch record. The investigation (Exception Report redacted) lacked root cause analysis and a formal Corrective Action Plan (CAP). Consignees were notified eight days after discovery, exceeding the 48-hour requirement of Paragraph X.E of the April 15, 2003 Amended Consent Decree. *
- Inspection Date
- June 23, 2008
- Product Type
- Devices
ID · c782f222-7202-4976-b36b-dfaa27b99a1c
Full citation text and observation details available on the Dashboard.