FDA 483 - Anderson Holdings Inc. - February 19, 2016
Discuss this record with AI
Document or profile
One record shows the event. A profile shows the pattern.
Buy this document for the source file and details behind this single event.
Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.
This FDA Form 483 details deficiencies at a facility producing sterile drug products, including Cyclosporin 2% ophthalmic solution and Tri-Mix 30-1-10.
**Aseptic Processing Area Deficiencies:** * **Cleaning and Disinfection:** The ISO 5 glove box's front panel is fully opened for daily cleaning, exposing the aseptic area to non-sterile gowning and ISO 8 room air without impact evaluation. Non-sterile solutions (Process LpH st, Vespelne Ise, Sporicidin) and non-sterile, non-shedding wipes are used in the ISO 5 glove box. Dilution of cleaning agents (Process LpH st, Vespelne Ise) with distilled water is not documented. Cleaning logs lack specific cleaning agent documentation for daily/monthly cleanings of ISO 5 and ISO 8 areas. * **Environmental Monitoring:** Volumetric viable air and surface contact monitoring in ISO classified areas are only monthly; no routine monitoring of the ISO 5 glove box during aseptic operations (3-4 days/week). Personnel monitoring (fingertip plating) is only during semi-annual media fills, not after routine sterile processing, and does not adhere to the specified frequency. ISO 8 room air pressure is documented daily, but continuous pressure differential monitoring for the ISO 5 glove box is absent. Positive low-level viable air monitoring results in the ISO 8 clean
ID · f19b8302-f4a4-44e1-81d7-365c1f3fc810
Full citation text and observation details available on the Dashboard.