FDA 483 - Bayview Pharmacy, Inc. - August 18, 2016
Discuss this record with AI
Document or profile
One record shows the event. A profile shows the pattern.
Buy this document for the source file and details behind this single event.
Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.
The FDA Form 483 inspection revealed multiple violations concerning aseptic processing, environmental control, and cross-contamination prevention. Personnel were observed blocking first-pass air in the ISO 5 zone, reaching into the Laminar Flow Hood with non-sterile attire (frock, dust mask, hair cover exposing face/eyes), and compromising sterility by placing vial stoppers face-down on a wipe. On 08/09/2016 and 08/10/2016, a pharmacist's upper body and head broke the ISO 5 plane during aseptic filling of Acetylcysteine 10% (PF) Nebulizer INH SOLN (Lot # 08082016@10) and TRI-MIX, leading to lot discards. Logged Formula Worksheets were placed in the ISO 5 hood, potentially disrupting airflow, also resulting in lot discards for Acetylcysteine and TRI-MIX.
The ISO 7 Cleanroom temperature reached 79°F on 08/09/2016, causing visible perspiration, with logs showing temperatures exceeding 78°F on twelve days (May 2016-present), peaking at 81°F. Facility design allowed poor quality air into higher classified areas, and no dynamic airflow assessment existed for the ISO 5 hood.
Highly potent drugs, including hormones (progesterone, estradiol
- Person
ID · ceb2f214-29c4-47b4-917a-641e2a5b65bf