Attention www.globalkeysolutions.net is now www.keypedia.com, read the full press release here.
KeyPedia LogoKeyPedia Icon
  1. Home
  2. /
  3. Records
  4. /
  5. 483
  6. /
  7. Biocon Sdn. Bhd. (Company No. 201101002193)
483
•Biocon Sdn. Bhd. (Company No. 201101002193)•July 20, 2023

FDA 483 - Biocon Sdn. Bhd. (Company No. 201101002193) - July 20, 2023

View on Dashboard

Your cart

Your cart is empty.

Browse public document pages and click Buy this document. We'll ask for your email at checkout, no account needed up front.

Browse documents

Discuss this record with AI

ChatGPT

Claude

Perplexity

Grok

Copilot

Record Details

An FDA inspection of Biocon Sdn. Bhd.'s drug and device manufacturing facility in Johor, Malaysia, conducted from July 10-20, 2023, revealed significant deviations from Current Good Manufacturing Practice (CGMP) regulations, as documented in an FDA Form 483.

For drug manufacturing, repeat observations included inadequate procedures to prevent microbiological contamination during sterile production, such as blocked aseptic airflow and insufficient sanitization of equipment. The company also failed to conduct integrity testing for stoppers and vials, compromising sterility assurance for distributed injectable products. Investigations into out-of-trend stability results and out-of-specification laboratory findings were consistently deficient, with scientifically unjustified root causes and a failure to retest affected batches. Environmental controls were inadequate, lacking written procedures for managing differential pressure losses in aseptic areas. Furthermore, test method transfers were not properly validated, incoming component quality was not routinely verified, and refresher CGMP training for Process Research & Development personnel was lacking.

Regarding medical devices, the inspection found an inadequate risk analysis for controlling and testing the injection force of a finished product, despite receiving over 1600 complaints about the device failing to administer medication. Corrective and preventive actions (CAPA) for these device issues were inadequately documented and failed to comprehensively test retention samples.

Biocon Sdn. Bhd. is required to provide a detailed response to the FDA outlining corrective and preventive actions to address these observations and ensure compliance with regulatory standards.

Company
Biocon Sdn. Bhd. (Company No. 201101002193)
Inspection Date
July 20, 2023
Office
Division of Pharmaceutical Quality Operations IV
People
  • Eileen A. Liu
  • Patty P. Kaewussdangkul (Investigator)
  • Daniel J. Lahar (Cso)
  • Rong Guo
Open in Dashboard

ID · 496a0f4c-3484-4189-944e-51e3808f290d

Violation Codes4
21 U.S.C. 324(a)(4)21 CFR 21021 CFR 211FD&C Act 801(a)(3)

Full citation text and observation details available on the Dashboard.

footer
Global Key Solutions
Regulatory Data Transformed
Contact
New York Office:
370 Jay Street 7th Floor
Brooklyn, NY 11201
Scranton Office:
Scranton Enterprise Center, Suite 217
201 Lackawanna Avenue
Scranton, PA, 18503
🇺🇸+1 917-789-5099
🇪🇺+48 532-447-507
info@globalkeysolutions.net
Quick Links
HomePlatform OverviewMedia
KeyPedia™ Lite
Browse HubDatabase DirectoryRecordsCompaniesOfficesPeopleCareersAbout UsFounding TeamMeet Our ExpertsPartners
Legal & Ethics
Privacy PolicyTerms of ServiceOur Values & MissionCode of Ethics & AI Policy
©2026, Global Key Solutions All rights reserved.