Attention www.globalkeysolutions.net is now www.keypedia.com, read the full press release here.
KeyPedia LogoKeyPedia Icon
  1. Home
  2. /
  3. Records
  4. /
  5. 483
  6. /
  7. Brookfield Medical/Surgical Supplies, Inc.
483
•Brookfield Medical/Surgical Supplies, Inc.•April 4, 2022

FDA 483 - Brookfield Medical/Surgical Supplies, Inc. - April 04, 2022

View on Dashboard

Your cart

Your cart is empty.

Browse public document pages and click Buy this document. We'll ask for your email at checkout, no account needed up front.

Browse documents

Discuss this record with AI

ChatGPT

Claude

Perplexity

Grok

Copilot

Document or profile

One record shows the event. A profile shows the pattern.

Buy this document for the source file and details behind this single event.

Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.

Explore Brookfield Medical/Surgical Supplies, Inc.
Record Details

The FDA Form 483 documents observations from an inspection of a facility producing Betamethasone Sodium Phosphate, (b)(4) solutions, Methylprednisolone Acetate, and Triamcinolone suspensions.

Several facility and equipment issues were noted: brownish rust-like material on a bracket in an ISO-5 laminar flow hood used for aseptic production; chipped paint on an ISO-8 Ante Room door damper, where sterile gowning, weighing, and formulation occur; and brownish stains in the unclassified Prep Room sink used for washing production equipment.

Quality system and manufacturing deficiencies include the routine use of a household cleaner for glassware and equipment without evidence of its ability to remove pharmaceutical residues or if it leaves residues. Smoke studies from 2021 for non-terminally sterilized products were inadequate, lacking full assessment of ISO-7 and ISO-5 air interactions under dynamic conditions. The firm failed to qualify (map) a refrigerator/freezer used for storing Betamethasone Sodium Phosphate, USP, and environmental monitoring media, to evaluate temperature distribution.

Critical findings relate to visual inspection: the SOP "Visual Inspection of Sterile Drug Products" and batch records lack defined release criteria for minor, major, or critical defects, impacting consistency among inspectors. Furthermore, the visual inspection test kits do not include all known defects, such as "Growth."

Company
Brookfield Medical/Surgical Supplies, Inc.
Inspection Date
April 4, 2022
Product Type
Drugs
Office
New England District Office
People
  • Erik W. Koester (Investigator)
  • Jonah S. Ufferfilge (Regional Manager)
Open in Dashboard

ID · e1dd1001-63f5-44cb-a8fc-5ac4daa11a75

Violation Codes4
21 CFR 21021 CFR 21121 U.S.C. 324(a)(4)21 U.S.C. 905(j)

Full citation text and observation details available on the Dashboard.

KeyPedia
Regulatory Data Transformed
Contact
New York Office:
370 Jay Street 7th Floor
Brooklyn, NY 11201
Scranton Office:
Scranton Enterprise Center, Suite 217
201 Lackawanna Avenue
Scranton, PA, 18503
🇺🇸+1 917-789-5099
🇪🇺+48 532-447-507
info@globalkeysolutions.net
Quick Links
HomePlatform OverviewMedia
KeyPedia™ Lite
Browse HubDatabase DirectoryRecordsCompaniesOfficesPeopleCareersAbout UsFounding TeamMeet Our ExpertsPartners
Legal & Ethics
Privacy PolicyTerms of ServiceOur Values & MissionCode of Ethics & AI Policy
©2026 KeyPedia™ | Global Key Solutions Corp. All rights reserved.