FDA 483 - Central Admixture Pharmacy Services, Inc. - February 27, 2013
Discuss this record with AI
Document or profile
One record shows the event. A profile shows the pattern.
Buy this document for the source file and details behind this single event.
Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.
The FDA Form 483 details significant deficiencies at a drug product manufacturing facility, impacting the production of sterile products like Oxytocin, Adenocaine, Lipid Syringes, TPN, Cardioplegic Solution, Continuous Renal Replacement Therapy, and Diltiazem.
Key violations include: - **Inadequate Laboratory Controls:** No established sterility or endotoxin testing procedures for each batch prior to release and distribution. Products are distributed before receiving passing results from an outside laboratory. - **Microbiological Contamination Prevention:** Procedures to prevent contamination of sterile drug products are not fully established or followed. - **Contaminant Ingress:** Insufficient procedures and controls to mitigate contaminant ingress into ISO 5 hoods. - **Gowning and Aseptic Technique Deficiencies:** - Personnel observed with exposed skin (neck, face) entering hoods, violating laminar air space. - Gowning SOP is silent on sterile gowning requirements. - Personnel not wearing goggles, hoods, hair nets, or face masks. - Inconsistent hand sanitization; some personnel applied sanitizers without proper rubbing. - Glove and sterile sleeve change-out intervals are not detailed in procedures, leading to personnel working extended periods without changes. - **Equipment and Area Cleanliness:** - Plastic holders in ISO 5 hoods, containing unsterile items, are not removed and cleaned daily. - Aftermarket hood guards, not part of original design, are
ID · 7893a59d-bf07-443c-bf6a-516690adca73
Full citation text and observation details available on the Dashboard.