Attention www.globalkeysolutions.net is now www.keypedia.com, read the full press release here.
KeyPedia LogoKeyPedia Icon
  1. Home
  2. /
  3. Records
  4. /
  5. 483
  6. /
  7. Drug Depot, LLC., dba APS Pharmacy
483
•Drug Depot, LLC., dba APS Pharmacy•January 22, 2016

FDA 483 - Drug Depot, LLC., dba APS Pharmacy - January 22, 2016

View on Dashboard

Your cart

Your cart is empty.

Browse public document pages and click Buy this document. We'll ask for your email at checkout, no account needed up front.

Browse documents

Discuss this record with AI

ChatGPT

Claude

Perplexity

Grok

Copilot

Record Details

The FDA Form 483 details numerous deficiencies at a facility producing sterile drug products including Methylcobalamin, HCG, Testosterone Cypionate, and Sermorelin.

Key violations include the lack of validation for sterilization processes for drug products, container/closures, and their storage hold times. Calibration procedures and documentation for equipment, including that used for glassware and finished product vials, are absent. Partially stoppered vials are exposed to less than ISO 5 air during filling, and personnel fail to sanitize items before placing them into the laminar flow hood. Personnel also place their heads inside the laminar flow hood during sterile drug preparation.

Media fills are deficient, not accurately simulating production or challenging conditions, and specific media fill data for HCG vial filling is missing. Environmental monitoring is inadequate, with air sampling (viable and non-viable) and surface sampling in classified areas only performed monthly, not daily. Continuous or periodic air pressure differential monitoring is not conducted. Dynamic airflow pattern studies (smoke studies) have not been performed in laminar flow hoods.

Personnel monitoring, including fingertip sampling and gowning material sampling, is not conducted daily. Non-sterile disinfectants are used, and no sporicidal agent is employed for classified areas. Disinfectant efficacy documentation is lacking. Gowning qualifications are not conducted, and non-sterile gowning components are used. Personnel were observed sliding hands on gowns after hanging them.

Sterility testing is not validated for interference or low-level organism detection,

Company
Drug Depot, LLC., dba APS Pharmacy
Inspection Date
January 22, 2016
Product Type
Drugs
Office
Florida District Office
People
  • Michael H. Tollon (Approval Manager)
  • Jennifer Lalama
Open in Dashboard

ID · 5b6d37cc-fcde-4b82-b4b6-f9f188e608c9

Violation Codes10
21 CFR 21121 CFR 211.113(b)21 CFR 211.100(a)FD&C Act 801(a)(3)FD&C Act 501(a)(2)(B)21 CFR 211.68(b)21 CFR 211.194(a)FD&C Act 502(a)21 CFR 211.84(d)(2)21 U.S.C. 355(d)

Full citation text and observation details available on the Dashboard.

footer
Global Key Solutions
Regulatory Data Transformed
Contact
New York Office:
370 Jay Street 7th Floor
Brooklyn, NY 11201
Scranton Office:
Scranton Enterprise Center, Suite 217
201 Lackawanna Avenue
Scranton, PA, 18503
🇺🇸+1 917-789-5099
🇪🇺+48 532-447-507
info@globalkeysolutions.net
Quick Links
HomePlatform OverviewMedia
KeyPedia™ Lite
Browse HubDatabase DirectoryRecordsCompaniesOfficesPeopleCareersAbout UsFounding TeamMeet Our ExpertsPartners
Legal & Ethics
Privacy PolicyTerms of ServiceOur Values & MissionCode of Ethics & AI Policy
©2026, Global Key Solutions All rights reserved.