FDA 483 - Eugia SEZ Private Limited - February 29, 2024
Discuss this record with AI
Document or profile
One record shows the event. A profile shows the pattern.
Buy this document for the source file and details behind this single event.
Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.
The FDA Form 483 details observations from an inspection of a facility manufacturing sterile drug products, specifically Injection USP.
**Violations and Observations:**
* **Aseptic Processing Deficiencies:** * Failure to follow procedures EP4-PR-SOP-042 (Aseptic Area Guidelines) and EP4-MB-SOP-028 (Viable Monitoring Program). * Interventions into critical areas during aseptic manufacturing (e.g., removing stuck vials, passing items, cleaning) were not replicated during aseptic process simulations to assess risk. * Operators failed to perform personnel monitoring after interventions into critical areas as mandated by EP4-MB-SOP-028. * Lack of slow and deliberate movements during interventions, contrary to aseptic process simulation techniques. * Failure to sanitize areas after interventions or clear manipulated vials from the line. * No disinfectant efficacy study for tubing used for drug product transfer in the Grade A filling area. * No written procedure for cleaning step ladders and Laminar Airflow Cabinets in Grade A and B areas, and no routine monitoring of these items. Microbial growth was observed on a step ladder sample.
* **Quality Control and Data Integrity Issues:** * Failure to follow SOP-HO-CQA-SOP-072 (Enumeration of Microbial Colonies); a personnel monitoring plate with one
- Company
- Eugia SEZ Private Limited
- Inspection Date
- February 29, 2024