FDA 483 - Fagron Compounding Services - March 24, 2022
Discuss this record with AI
Document or profile
One record shows the event. A profile shows the pattern.
Buy this document for the source file and details behind this single event.
Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.
An FDA inspection of Fagron Compounding Services, an outsourcing facility located at 8710 E 34th St N, Wichita, KS, was conducted from March 1 to March 24, 2022. The inspection identified six observations regarding deficient practices.
Observation 1 noted deficiencies in cleaning and disinfecting aseptic processing areas. Specific instances included the failure to clean the inside back of an ISO 5 Horizontal laminar flow hood prior to producing Moxifloxacin Lot # (b)(4) and Norepinephrine Bitartrate 32 mcg/mL Lot # (b)(4). Additionally, parts of an ISO 7 Cleanroom (Fill room (b)(4)), including a wall protrusion, areas around an ISO 5 hood, and the floor under a pump cart, were not cleaned.
Observation 2 highlighted the absence of written procedures for production and process controls to ensure drug product identity, strength, quality, and purity. This included a lack of equipment qualification for a (b)(4) transferred in January 2020, used for Sodium Thiosulfate 25% production. The master batch record for Sodium Thiosulfate 25% solution did not record the asset number for the (b)(4) used, and the SOP for the (b)(4) lacked a program for (b)(4) to (b)(4), impacting approximately (b)(4) batches of Sodium Thiosulfate 2