FDA 483 - Immunomedics, Inc. - March 10, 2020
Discuss this record with AI
Document or profile
One record shows the event. A profile shows the pattern.
Buy this document for the source file and details behind this single event.
Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.
On March 10, 2020, the FDA issued a Form 483 to Immunomedics, Inc., a drug substance intermediate manufacturer located in Morris Plains, NJ, following an inspection from March 2-10, 2020. The inspection revealed ten observations related to quality system and manufacturing deficiencies.
Key observations include: 1. **Microbiological Contamination Control:** Procedures and controls to prevent microbiological contamination of drug substance intermediates are not established. This includes a lack of procedures, gowning requirements, and QA review for dynamic smoke studies in ISO 5 Biological Safety Cabinets (BSCs), with studies not simulating worst-case conditions. Additionally, a filter used for sterilization is not routinely sterilized or integrity tested, and the water used for sterilization is not routinely tested for critical physical qualities. 2. **Quality Control Unit Responsibilities:** The responsibilities and procedures of the quality control unit are not fully followed. Final QA and microbiology review and approval for operations were not performed in a timely manner, leading to conditional approvals and ongoing production without complete release. Bare hands, bare forearms, and street clothes were observed within a BSC during dynamic smoke studies, and associated medium bottles were subsequently used without QA or microbiology evaluation. Chromatograms are not electronically or manually indicated for quality unit review. 3. **Inadequate/Unfollowed SOPs:** Standard Operating Procedures (SOPs) are inadequate or not followed. Examples include:
ID · 977f14da-5f9b-480a-9034-95991b8ebabc