Attention www.globalkeysolutions.net is now www.keypedia.com, read the full press release here.
KeyPedia LogoKeyPedia Icon
  1. Home
  2. /
  3. Records
  4. /
  5. 483
  6. /
  7. Infusion Systems of SW Florida Inc. dba Myerlee Pharmacy
483
•Infusion Systems of SW Florida Inc. dba Myerlee Pharmacy•July 20, 2017

FDA 483 - Infusion Systems of SW Florida Inc. dba Myerlee Pharmacy - July 20, 2017

View on Dashboard

Your cart

Your cart is empty.

Browse public document pages and click Buy this document. We'll ask for your email at checkout, no account needed up front.

Browse documents

Discuss this record with AI

ChatGPT

Claude

Perplexity

Grok

Copilot

Document or profile

One record shows the event. A profile shows the pattern.

Buy this document for the source file and details behind this single event.

Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.

Explore Infusion Systems of SW Florida Inc. dba Myerlee Pharmacy
Record Details

During an FDA inspection from July 13-20, 2017, Infusion Systems of SW Florida Inc. dba Myerlee Pharmacy, a producer of sterile and non-sterile drug products in Fort Myers, FL, was cited for nine observations, many of which were repeat findings.

Key violations include: 1. **Aseptic Deficiencies (Repeat Observation):** Personnel failed to sanitize gloved hands, touched workstation surfaces, had exposed skin inside the laminar flow hood (ISO 5), and cleaned improperly. Media fills were deficient, not simulating stressful conditions, sterilizing potential growth, or including growth promotion. 2. **Environmental Monitoring Deficiencies (Repeat Observation):** Fungus (Chaetomium spp., Alternaria spp.) was detected in ISO 7 areas without documented corrective measures. Air sampling was not performed during dynamic conditions, and continuous air pressure differential monitoring was absent, with out-of-limit readings uncorrected. Personnel monitoring (e.g., fingertip sampling, gowning material sampling) was inadequate and not conducted during operations. 3. **Sterilization Process Validation (Repeat Observation):** Sterilization processes for equipment (e.g., [redacted] for glassware, [redacted] for stir bars/vial stoppers) were not validated, lacking written calibration procedures or documentation like temperature mapping. 4. **Contamination Prevention:** Personnel failed to sterilize a vial crimper or

Company
Infusion Systems of SW Florida Inc. dba Myerlee Pharmacy
Inspection Date
July 20, 2017
Product Type
Drugs
Office
Florida District Office
People
  • June P. Page
  • Jennifer Lalama
Open in Dashboard

ID · f2932c03-8815-4ff7-9f77-2ba49f0c2b57

Violation Codes2
21 CFR 21021 CFR 211

Full citation text and observation details available on the Dashboard.

KeyPedia
Regulatory Data Transformed
Contact
New York Office:
370 Jay Street 7th Floor
Brooklyn, NY 11201
Scranton Office:
Scranton Enterprise Center, Suite 217
201 Lackawanna Avenue
Scranton, PA, 18503
🇺🇸+1 917-789-5099
🇪🇺+48 532-447-507
info@globalkeysolutions.net
Quick Links
HomePlatform OverviewMedia
KeyPedia™ Lite
Browse HubDatabase DirectoryRecordsCompaniesOfficesPeopleCareersAbout UsFounding TeamMeet Our ExpertsPartners
Legal & Ethics
Privacy PolicyTerms of ServiceOur Values & MissionCode of Ethics & AI Policy
©2026 KeyPedia™ | Global Key Solutions Corp. All rights reserved.