FDA 483 - Innovative Compounding Pharmacy - April 17, 2015
Discuss this record with AI
Document or profile
One record shows the event. A profile shows the pattern.
Buy this document for the source file and details behind this single event.
Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.
The FDA Form 483 documents observations from an inspection of a drug manufacturing facility.
**Facility and Operation Details:** The inspection covered areas involved in aseptic processing, including an ISO-5 LAF hood, ISO-7 anteroom, and buffer room. The facility manufactures sterile injectable products, including Testosterone Cypionate 200mg/ml.
**Violations and Observations:** 1. **Unclean Conditions:** Spatters were observed on the ceiling of the ISO-5 LAF hood on April 13, 2015, despite being logged as clean on April 10, 2015. 2. **Deficient Cleaning/Disinfection:** Non-sterile wipes were used for the ISO-5 LAF hood, and non-sterile, non-lint-free mop-heads were used for ISO-7 areas. Cleaning procedures for the ISO-5 LAF hood lacked detail. No records demonstrated disinfectant solution effectiveness throughout its period of use. 3. **Inadequate Environmental Monitoring:** Viable and non-viable particulate monitoring was never performed during routine aseptic filling. Glove touch plate monitoring was inconsistent. The pressure differential gauge between ISO-7 and unclassified areas was not continuously monitored, alarmed, or calibrated. Only one passageway was monitored. Pressure records from January 13 to April 13, 2015, showed 65% of readings below the required 0.0