FDA 483 - IntegraDose Compounding Services LLC - September 19, 2018
Discuss this record with AI
Document or profile
One record shows the event. A profile shows the pattern.
Buy this document for the source file and details behind this single event.
Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.
The FDA Form 483 details multiple observations regarding a pharmaceutical facility's quality control and manufacturing practices.
**Key Violations and Observations:**
* **Inadequate Out-of-Specification (OOS) Investigations:** The firm failed to thoroughly investigate OOS results for several drug products, releasing batches based solely on retesting without identifying a laboratory error or root cause. * **Ephedrine Sulfate 25mg/5mL Syringe (Lot 20180228EPH-1):** Released despite a positive (b)(4) result (indicating possible microbiological contamination) without adequate sterility failure investigation. * **Hydromorphone Syringes (Multiple Lots):** Several lots (20171025HYD-1, 20171219HYD-1, 20180123HYD-2, 20180329HYD-2, 20180531HYD-1) were released with potency results outside specifications (e.g., 132.6%, 135.9%, 136.7%, 130.1%, 127.9%, 127.8%, 94.8%, 93.8%, 93.6%, 106.