FDA 483 - Jiangsu Hengrui Pharmaceuticals Co., Ltd. (Huanghe Road Site) - January 16, 2024
Discuss this record with AI
Document or profile
One record shows the event. A profile shows the pattern.
Buy this document for the source file and details behind this single event.
Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.
This FDA Form 483 details multiple observations from an inspection of a facility manufacturing sterile drug products.
**Facility and Operations:** The inspection covered general parenteral workshops, including a filling room with a RABS (Restricted Access Barrier System) and associated Grade A, B, C, and D areas. The facility manufactures products like Injection USP.
**Violations and Observations:**
* **Aseptic Process Validation Deficiencies:** * Sterilization of product contact equipment (e.g., stopper drums) lacked outer wrapping and cover during transfer, compromising sterility. * Inadequate physical separation between Grade A and Grade B areas, and airflow visualization studies did not cover transitions. * Discrepancies between observed and recorded intervention times during filling (e.g., 3:58 pm - 4:03 pm observed vs. 4:00 pm - 4:01 pm recorded). * Procedure P-01 007 lacked clear definitions for intervention start/stop times. * Process simulation studies (media fills) were not representative of commercial operations, failing to adequately incorporate worst-case interventions (nature, frequency, duration). * Inadequate production operator requalification procedures for interventions; operators performing few or no interventions during media fills were still considered requalified.
* **Container Closure System Issues:** * Container closure integrity test for