FDA 483 - Maitland Labs of Central Florida - February 28, 2020
Discuss this record with AI
Document or profile
One record shows the event. A profile shows the pattern.
Buy this document for the source file and details behind this single event.
Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.
The FDA Form 483 details multiple deficiencies at an outsourcing facility producing sterile drug products, specifically Nalbuphine HCL, 10mg/1mL.
**Aseptic Processing & Environmental Control:** * Aseptic processing areas are deficient in cleaning and disinfection. Non-sterile disinfectant and wipes are used in the Cleanroom and ISO 5 Laminar Flow Hood, and sterile wipes shed particulates. * The firm failed to conduct a smoke study under dynamic conditions within the ISO-5 Laminar Flow Hood used for Nalbuphine HCL production.
**Quality System & Investigations:** * The firm failed to thoroughly review unexplained discrepancies. Specifically, 93 vials of Nalbuphine HCL, lot #20200108, failed visual inspection for fibers, but no investigation or corrective actions were taken. * Alarms (exhaust rate too fast, door unsealed) on the lyophilizer during processing of Nalbuphine HCL, lot #20200108, were not evaluated for their impact on the batch, despite subsequent maintenance.
**Stability & Testing:** * There is no written stability testing program. The firm failed to follow appropriate stability requirements (temperature/humidity) for Nalbuphine HCL, lot #2019111 R&D, lacking data to support a 12-month expiration date for lot #202001