FDA 483 - Meridian Medical Technologies, LLC a Subsidiary of Kindeva Drug Delivery, L.P. - February 13, 2012
Discuss this record with AI
Document or profile
One record shows the event. A profile shows the pattern.
Buy this document for the source file and details behind this single event.
Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.
The FDA Form 483 details multiple violations at a facility manufacturing Multichambered AutoInjectors (e.g., Atropine/Pralidoxime Chloride).
**Production and Process Control Deficiencies:** * **Batch 1M1726:** Production and process control procedures were not followed. * Raw data from 100% inspection for plunger placement rework was not documented; only final results were recorded. * Rework was not reviewed or approved by the Quality Unit. * Weight verification for container counts was not documented. * **Product Transfer:** SOP-MDP-GEN-00013-SL was not followed for Atropine batch 1M1726; the transfer form indicated a different transfer date than the carrier's sign-off. * **Annual Review:** Annual review of AtroPen product reserves was not approved by the statistical quality control supervisor by the due date of 3/31/2011, as required by SOP-QLC-SQC-00384-SL. Approval occurred on 6/27/2011.
**Aseptic Processing and Microbiological Contamination Control Issues:** * **SOP-PRO-FIL-00001-SL (General Aseptic Procedure) Not Followed:** * Operator was observed
- Inspection Date
- February 13, 2012
- Product Type
- Drugs
ID · 34e35ff2-99e5-41bf-9e91-bd244178edcd
Full citation text and observation details available on the Dashboard.