FDA 483 - Michigan Medicine - June 29, 2016
Discuss this record with AI
Document or profile
One record shows the event. A profile shows the pattern.
Buy this document for the source file and details behind this single event.
Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.
On June 29, 2016, the FDA issued a Form 483 to Stanley S. Kent, Chief Pharmacy Officer at the University of Michigan, a producer of sterile drug products located at 1500 E Medical Center Dr, Ann Arbor, MI. The inspection, conducted from June 6-29, 2016, identified eight observations.
Observation 1 noted inadequate investigations into multiple positive sterility test results for products like Bupivacaine, Phenylephrine, Calcium Gluconate, and Hydromorphone. Investigations failed to identify root causes, evaluate potential product/process impact, or implement sufficient corrective actions.
Observation 2 detailed inadequate aseptic practices and procedures. Issues included transferring items to ISO 5 areas without sanitization, placing non-sterile gauze in ISO 5 hoods, operators contacting ISO 5 items without re-sanitizing gloved hands, resting gloved hands/non-sterile gown sleeves on ISO 5 surfaces, and improper storage of sterile spray bottles. Smoke studies were also not performed under dynamic conditions.
Observation 3 cited deficiencies in aseptic processing area equipment and maintenance. This included cracks and seams in ISO 5 hood surfaces, unsecured ceiling tiles, unsealed gaps around sprinkler covers, surface damage on ceiling tiles, non-cleanable operator contact surfaces, damaged floor seams, unnecessary items in cleanrooms, and rust on a cleanroom refrigerator. HEPA filters in ISO 7 and
ID · 70ec50c4-f72e-47a1-8d10-129f917bab87