FDA 483 - Mylan Laboratories Limited - June 26, 2024
Discuss this record with AI
Document or profile
One record shows the event. A profile shows the pattern.
Buy this document for the source file and details behind this single event.
Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.
During an inspection from June 14-26, 2024, at Mylan Laboratories Limited (FEI 3010453141), a drug products manufacturer in Pithampur, India, the FDA observed several violations. Mr. Pramod Kumar Singh, Head of Operations - India and Africa, was issued the Form 483.
**Key Observations:**
* **Equipment Cleaning Deficiencies:** Non-dedicated equipment, including a HEPA filter chamber and duct in Block, used for manufacturing Tablets mg, showed white to off-white materials despite being in "Type A cleaning status." This indicates inadequate cleaning intervals to prevent contamination affecting drug product safety, identity, strength, quality, or purity. * **Inadequate Quality Unit Procedures:** The Quality Unit failed to provide scientific justification for sampling only "good tablets" after a rejected tablet was identified outside the acceptable weight range, as per SOP-000464236. This raises concerns about the reliability of quality control for variable batch sizes. * **Insufficient OOS Investigations:** Investigations into out-of-specification (OOS) results lacked scientific rationale for root cause determinations. An example cited was Laboratory Investigation PR ID: 3455440 (opened 28-Mar-2024) for Tablets, where OOS/OOT results were observed for Dissolution profile tests at 3 and 1