This FDA Form 483 documents observations from an inspection of a facility engaged in aseptic processing of drug products. The inspection revealed several deficiencies related to maintaining aseptic conditions, preventing microbiological contamination, environmental monitoring, cleaning and disinfection, and personnel gowning.

**Facility and Operations:** The facility utilizes an ISO 8 Ante Room for gowning and an ISO 7 Clean Room leading to an ISO 5 Hood for aseptic processing.

**Violations and Observations:**

1. **Aseptic Processing Area Design and Maintenance (21 CFR 211.42(c)(10)(iv)):** * **ISO 8 Ante Room:** * Personnel movement allowed gowned technicians to interact with un-gowned personnel before entering the Clean Room. * The room has porous, unsealed, and non-cleanable ceiling tiles. * **ISO 7 Clean Room Door:** Partially constructed of wood, which is not readily cleanable. * **Smoke Studies:** No evidence of dynamic smoke studies; vendor-conducted studies did not mimic actual processing conditions, and technicians were not present to simulate processing.

2. **Prevention of Microbiological Contamination (21 CFR 211.113(b)):** * Technicians introduced non-sterile components into the ISO 5 Hood without disinfection. * Technicians frequently exited the ISO

Company
Nemours Alfred I. duPont Hospital for Children
Inspection Date
June 29, 2016
Product Type
Drugs
Office
Philadelphia District Office
Person
  • Thomas E. Friel (Investigator )
Open in Dashboard

ID · 62dd2afc-d44d-455a-af2a-ca3e63526581

Violation Codes2
21 CFR 21021 CFR 211

Full citation text and observation details available on the Dashboard.

footer
Global Key Solutions
Regulatory Data Transformed
Contact
New York Office:
370 Jay Street 7th Floor
Brooklyn, NY 11201
Scranton Office:
Scranton Enterprise Center, Suite 217
201 Lackawanna Avenue
Scranton, PA, 18503
🇺🇸+1 917-789-5099
🇪🇺+48 532-447-507
info@globalkeysolutions.net
Quick Links
HomePlatform OverviewMedia
KeyPedia™ Lite
Browse HubDatabase DirectoryRecordsCompaniesOfficesPeopleCareersAbout UsFounding TeamMeet Our ExpertsPartners
Legal & Ethics
Privacy PolicyTerms of ServiceOur Values & MissionCode of Ethics & AI Policy
©2026, Global Key Solutions All rights reserved.