FDA 483 - People's Custom Rx and Clinical Care, LLC - July 29, 2015
Discuss this record with AI
Document or profile
One record shows the event. A profile shows the pattern.
Buy this document for the source file and details behind this single event.
Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.
From July 20-29, 2015, the FDA inspected People's Custom Rx and Clinical Care, LLC, a producer of sterile drug products in Memphis, TN. The inspection revealed nine observations regarding the firm's manufacturing practices and quality systems.
Observation 1 noted inadequate procedures to prevent microbiological contamination. A technician re-entered a clean room without changing garbing, non-sterile 99% Isopropyl Alcohol was used for sanitization, and non-sterile, reused gowning components were permitted.
Observation 2 cited deficiencies in environmental monitoring. Weekly air and surface monitoring was deemed inadequate, with insufficient sample points and infrequent monitoring of technicians' fingertips.
Observation 3 detailed issues with material flow, specifically the lack of decontamination for supplies and components before introduction into aseptic processing areas.
Observation 4 highlighted deficiencies in maintaining equipment for aseptic conditions. Smoke studies for ISO 5 hoods were not video recorded, documented, or performed under dynamic conditions, and pressure in controlled areas was only checked once daily.
Observation 5 identified a lack of validation for sterilization processes, including stock solutions, autoclaving rubber stoppers and finished drug products, depyrogenating/sterilizing glassware, and terminal sterilization of oil-based drug products.
Observation 6 reported issues with equipment calibration. A Boekel incubator for sterility samples was consistently out of range (25.2°C to 30.8°C vs. 22