Attention www.globalkeysolutions.net is now www.keypedia.com, read the full press release here.
KeyPedia LogoKeyPedia Icon
  1. Home
  2. /
  3. Records
  4. /
  5. 483
  6. /
  7. PETNET Solutions, Inc.
483
•PETNET Solutions, Inc.•December 2, 2025

FDA 483 - PETNET Solutions, Inc. - December 02, 2025

View on Dashboard

Your cart

Your cart is empty.

Browse public document pages and click Buy this document. We'll ask for your email at checkout, no account needed up front.

Browse documents

Discuss this record with AI

ChatGPT

Claude

Perplexity

Grok

Copilot

Document or profile

One record shows the event. A profile shows the pattern.

Buy this document for the source file and details behind this single event.

Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.

Explore PETNET Solutions, Inc.
Record Details

An FDA inspection, conducted from late November to early December 2025 and issued on December 4, 2025, identified significant deficiencies at a pharmaceutical manufacturing facility (company name redacted). The observations, made under the Federal Food, Drug, and Cosmetic Act, highlight critical concerns in both laboratory control and facilities management, potentially impacting the safety and quality of sterile PET drug products.

The primary issues involved the company's laboratory control system, specifically with Gas Chromatography (GC) equipment. The firm experienced over 100 repeat system suitability failures for its GC equipment without conducting root cause investigations. Instead, initial failing runs were invalidated, and subsequent successful runs were accepted, raising questions about the reliability of test results for critical drug products.

Furthermore, deficiencies in the facilities and equipment system revealed a failure to adequately implement and document cleaning procedures. Specific concerns included operators not sanitizing gowning sleeves before re-entering ISO classified areas, leading to potential contamination of sterile product assembly surfaces. The company also failed to document disinfectant contact times as required by its own procedures, hindering assurance of effective sanitation. Lastly, there was a lack of established controls for ready-to-use disinfectant spray bottles, allowing improper handling and increasing the risk of cross-contamination.

These observations indicate conditions that could compromise the identity, strength, quality, or purity of drug products. The company is required to review these findings and submit a detailed plan outlining comprehensive corrective actions to address each identified deficiency.

Company
PETNET Solutions, Inc.
Inspection Date
December 2, 2025
Product Type
Drugs
Office
San Francisco District Office
People
  • Gloria E. Andia
  • Jolanna A. Norton (Investigator)
Open in Dashboard

ID · 5a7be473-47a6-4953-9785-8fac2c3913f3

KeyPedia
Regulatory Data Transformed
Contact
New York Office:
370 Jay Street 7th Floor
Brooklyn, NY 11201
Scranton Office:
Scranton Enterprise Center, Suite 217
201 Lackawanna Avenue
Scranton, PA, 18503
🇺🇸+1 917-789-5099
🇪🇺+48 532-447-507
info@globalkeysolutions.net
Quick Links
HomePlatform OverviewMedia
KeyPedia™ Lite
Browse HubDatabase DirectoryRecordsCompaniesOfficesPeopleCareersAbout UsFounding TeamMeet Our ExpertsPartners
Legal & Ethics
Privacy PolicyTerms of ServiceOur Values & MissionCode of Ethics & AI Policy
©2026 KeyPedia™ | Global Key Solutions Corp. All rights reserved.