FDA 483 - RX South DBA RX3 Compounding Pharmacy LLC - December 14, 2012
Discuss this record with AI
Document or profile
One record shows the event. A profile shows the pattern.
Buy this document for the source file and details behind this single event.
Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.
The FDA Form 483 details numerous violations concerning the manufacturing of Medi-bolic Booster Injectable and Pyridoxine/Thiamine 100mg/mL/20mg/mL Injectable.
**Key Violations and Observations:**
* **Sterility Testing Deficiencies:** * Lack of routine sterility testing for most lots of both products manufactured prior to 11/5/2012 (only 4 out of 120+ Medi-bolic lots and 4 out of redacted Pyridoxine/Thiamine lots were tested). * Sterility testing procedures did not follow USP Chapter <71> requirements, using only TSB media instead of both FTM and TSB. * **Stability Testing Issues:** * Absence of a written stability testing program to continuously monitor batches on the market. * One Pyridoxine/Thiamine lot (02112008@1748) failed potency/purity specifications at the 60-day time point (88.23% vs. redacted specification), with no investigation conducted. * No analytical data supported the 90-day expiry for Medi-bolic Booster Injectable. * **Product Release and Potency Testing:** * Lack of routine final product potency testing for both injectables; only four lots of each product were tested for identity
ID · 233d54f7-974a-4eb3-bc6a-e4144c9ec919
Full citation text and observation details available on the Dashboard.