FDA 483 - Westlab Pharmacy, Inc. dba Westlab Pharmacy - August 15, 2018
Discuss this record with AI
Document or profile
One record shows the event. A profile shows the pattern.
Buy this document for the source file and details behind this single event.
Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.
The FDA Form 483 details multiple observations from an inspection. The facility's ISO 5 classified aseptic processing area, used for mitomycin and cyclosporine drug products (e.g., Mitomycin Oph 0.02% Lot 06152018@13, Cyclosporin Aqueous 0.5% solution Lot 06132018@43), was located within a non-classified room. Non-sterile disinfecting agents and cleaning wipes were used in ISO 5 areas; specifically, non-sterile wipes were used to clean the ISO 5 Laminar Airflow Workstation (LAFW) prior to a media fill on 08/06/18, and non-sterile products like (b)(4) were used for cleaning.
Non-pharmaceutical grade components were used in drug product formulations, including (b)(4) in Alprostadil 500mcg/mL injectable (Lots 03182018@42, 07252018@17), and in non-sterile products such as Vancomycin/Water 250mg/mL solution (Lot 07022018@53). Personnel engaged in aseptic processing were observed with exposed hands, specifically an operator donning sterile gloves inside the ISO 5 LAFW. The ISO 5 LAFW had difficult-