Attention www.globalkeysolutions.net is now www.keypedia.com, read the full press release here.
KeyPedia LogoKeyPedia Icon
  1. Home
  2. /
  3. Records
  4. /
  5. Eir
  6. /
  7. Hydrox Laboratories
EIR
•Hydrox Laboratories•June 24, 2021

FDA EIR - Hydrox Laboratories - June 24, 2021

View on Dashboard

Your cart

Your cart is empty.

Browse public document pages and click Buy this document. We'll ask for your email at checkout, no account needed up front.

Browse documents

Discuss this record with AI

ChatGPT

Claude

Perplexity

Grok

Copilot

Document or profile

One record shows the event. A profile shows the pattern.

Buy this document for the source file and details behind this single event.

Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.

Explore Hydrox Laboratories
Record Details

Hydrox Laboratories, an over-the-counter drug and cosmetic manufacturer in Elgin, IL, underwent an FDA inspection from May 24 to June 24, 2021. This for-cause inspection was conducted under a 1998 Consent Decree, which mandates the firm's adherence to Current Good Manufacturing Practice (cGMP) regulations for drug product manufacturing. The regulatory framework includes 21 CFR 211.113(a) concerning microbiological contamination control and 21 CFR 211.165(b) for laboratory testing and product release.The inspection identified nine significant observations on Form FDA 483. Key violations included a recurring failure to perform required microbial testing of the production water system, with 14 instances of missed testing since 2018. The firm also failed to test finished drug products for Burkholderia cepacia and lacked a risk assessment for this. Additionally, water system B. cepacia testing methods were not validated as equivalent to official compendial standards, and alternative diluents used in testing lacked suitability studies.Further issues involved equipment marked clean but containing visible residues, equipment in disrepair or poorly designed, and susceptible to contamination. Cleaning validation for new equipment was lacking, and documented cleaning checks were not always executed. Deficiencies in quality systems included failure to initiate timely investigations and improper invalidation of laboratory data.Management committed to addressing these observations and submitting a written response within fifteen business days, emphasizing the ongoing requirement for cGMP compliance under the Consent Decree.

Company
Hydrox Laboratories
Inspection Date
June 24, 2021
Product Type
Drugs
Office
Chicago District Office
People
  • Michele L. Glendenning
  • Kevin P. Regan (GDUFA Pharmaceutical Investigator)
Open in Dashboard

ID · ac7d8996-76d3-4759-a65d-e6537d6f623f

Violation Codes10
21 CFR 211.100(b)21 CFR 21121 CFR 211.67(a)21 CFR 211.67(b)(5)21 CFR 211.167(b)21 CFR 211.19221 CFR 211.113(a)21 CFR 211.6321 CFR 211.67(b)(6)FD&C Act 704

Full citation text and observation details available on the Dashboard.

KeyPedia
Regulatory Data Transformed
Contact
New York Office:
370 Jay Street 7th Floor
Brooklyn, NY 11201
Scranton Office:
Scranton Enterprise Center, Suite 217
201 Lackawanna Avenue
Scranton, PA, 18503
🇺🇸+1 917-789-5099
🇪🇺+48 532-447-507
info@globalkeysolutions.net
Quick Links
HomePlatform OverviewMedia
KeyPedia™ Lite
Browse HubDatabase DirectoryRecordsCompaniesOfficesPeopleCareersAbout UsFounding TeamMeet Our ExpertsPartners
Legal & Ethics
Privacy PolicyTerms of ServiceOur Values & MissionCode of Ethics & AI Policy
©2026 KeyPedia™ | Global Key Solutions Corp. All rights reserved.