EIR
•Medtronic MiniMed, Inc.•March 24, 2017

FDA EIR - Medtronic MiniMed, Inc. - March 24, 2017

View on Dashboard

Your cart

Your cart is empty.

Browse public document pages and click Buy this document. We'll ask for your email at checkout, no account needed up front.

Browse documents

Discuss this record with AI

ChatGPT

Claude

Perplexity

Grok

Copilot

Document or profile

One record shows the event. A profile shows the pattern.

Buy this document for the source file and details behind this single event.

Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.

Explore Medtronic MiniMed, Inc.
Record Details

An FDA inspection was conducted at Medtronic MiniMed, Inc. in Northridge, CA, from March 7 to March 24, 2017. The inspection focused on the company's medical device manufacturing, particularly the Paradigm Real-Time Revel infusion pump system, under a Postmarket Inspection request for Class II and III devices. The regulatory framework covered included aspects of the Quality System Regulation (21 CFR 820), specifically reviewing Corrective & Preventive Action (CAPA) and Production & Process Controls subsystems. The inspection revealed significant deficiencies, documented in an FDA Form 483, primarily related to the acceptance of incoming products. Key violations included the inadequate establishment and adherence to procedures for incoming product acceptance. This involved automatically releasing numerous lots of molded polycarbonate sleeves and sterile infusion sets for production without required inspection, issuing Certificates of Conformance without actual testing, and a lack of proper documentation for accepted materials. Issues also arose from early electronic release of materials before inspection completion, missing Acceptable Quality Level (AQL) specifications, and the inability to locate certain lots designated for quality inspection. Additionally, management discussions highlighted that product hold orders were not implemented promptly for nonconforming items, bicarbonate buffer sensor testing procedures were incomplete, and device history records for infusion sets lacked comprehensive acceptance documentation. In response, James R. Dabbs, Vice President of Quality Assurance, acknowledged the observations, promised to correct all identified issues, and committed to submitting a written response to the FDA within 15 business days.

Company
Medtronic MiniMed, Inc.
Inspection Date
March 24, 2017
Product Type
Devices
Office
Center for Devices and Radiological Health
Person
  • Janet Pulver (Investigator)
Open in Dashboard

ID · 0828b285-94be-4c25-ae52-490883206e39

Violation Codes7
21 CFR 820.15021 CFR 820.19821 CFR 820.3021 CFR 820.80(b)21 CFR 820.90(a)21 CFR 80321 CFR 820.50

Full citation text and observation details available on the Dashboard.

KeyPedia
Regulatory Data Transformed
Contact
New York Office:
370 Jay Street 7th Floor
Brooklyn, NY 11201
Scranton Office:
Scranton Enterprise Center, Suite 217
201 Lackawanna Avenue
Scranton, PA, 18503
🇺🇸+1 917-789-5099
🇪🇺+48 532-447-507
info@globalkeysolutions.net
Quick Links
HomePlatform OverviewMedia
KeyPedia™ Lite
Browse HubDatabase DirectoryRecordsCompaniesOfficesPeopleCareersAbout UsFounding TeamMeet Our ExpertsPartners
Legal & Ethics
Privacy PolicyTerms of ServiceOur Values & MissionCode of Ethics & AI Policy
©2026 KeyPedia™ | Global Key Solutions Corp. All rights reserved.