FDA WARNING_LETTER - Auto-Chlor System LLC - July 18, 2022
Discuss this record with AI
Document or profile
One record shows the event. A profile shows the pattern.
Buy this document for the source file and details behind this single event.
Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.
On December 20, 2022, the FDA issued a Warning Letter to Auto-Chlor System LLC following an inspection from July 5-18, 2022, at their Hapeville, GA facility. The inspection revealed significant Current Good Manufacturing Practice (CGMP) violations for finished pharmaceuticals, rendering their drug products adulterated.
Key violations include: 1. **Failure to establish and follow written procedures for equipment cleaning and maintenance (21 CFR 211.67(b))**: The firm used the same equipment for drug products and industrial cleaners, risking cross-contamination, and observed inadequate cleaning. 2. **Failure to test components for identity, purity, strength, and quality (21 CFR 211.84(d)(1) and 211.84(d)(2))**: The firm did not test incoming ethanol for methanol and relied on unqualified supplier Certificates of Analysis. Additionally, the firm used (b)(4) water as a component without testing for suitability or meeting USP purified water monograph standards. 3. **Failure to establish adequate written procedures for production and process control (21 CFR 211.100(a))**: The firm lacked process validation and equipment qualification for hand sanitizer manufacturing. 4. **Quality control unit failure to ensure CGMP compliance (21 CFR 211.22)**: The Quality
ID · 5ed8b14c-7dc9-4ef6-be2e-8274310149f7
Full citation text and observation details available on the Dashboard.