•Beckman Coulter Inc.•December 11, 2023

FDA WARNING_LETTER - Beckman Coulter Inc. - December 11, 2023

View on Dashboard

Your cart

Your cart is empty.

Browse public document pages and click Buy this document. We'll ask for your email at checkout, no account needed up front.

Browse documents

Discuss this record with AI

ChatGPT

Claude

Perplexity

Grok

Copilot

Record Details

The FDA issued a Warning Letter to Ms. Montgomery, manufacturer of DxI 9000 Access Immunoassay analyzer instrument system and assays, following an inspection from November 1, 2023, to December 11, 2023. The inspection revealed that the devices are adulterated as manufacturing methods, facilities, or controls do not conform to Quality System regulation (21 CFR Part 820).

Key violations include: 1. **Failure to adequately establish and maintain procedures for risk analysis (21 CFR 820.30(g))**: The firm's "Product Safety Risk Management" procedure had insufficient definitions for certain severity of harm categories, leading to incorrect severity ratings for various assays' false result failure modes (e.g., HBs Ag, HBc IgM, HBc Ab, Troponin I, Digoxin). Additionally, the firm failed to use semi-quantitative ranges for occurrence ratings when data was available, deviating from their own procedures. The firm's responses were deemed inadequate, lacking proposed updates, justifications, or systemic corrective actions.

2. **Failure to adequately establish procedures for corrective and preventative actions (21 CFR 820.100(a))**: Procedures for analyzing quality data to identify nonconforming product causes were inadequate. Specifically, the "Manufacturing Non-Conformance CAPA Eligibility" procedure lacked uniform processes and clear criteria for escalating nonconformances to CAP

Company
Beckman Coulter Inc.
Inspection Date
December 11, 2023
Product Type
Devices
Office
Division of Medical Device and Radiological Health Operations Central
Person
  • Blake Bevill (Director)
Open in Dashboard

ID · 098bb7cc-ea86-4c66-9ab6-da431b038d96

Violation Codes7
21 U.S.C. 321(h)21 U.S.C. 351(h)21 CFR 82021 CFR 820.30(g)21 CFR 820.100(a)21 CFR 820.90(a)21 CFR 820.30(i)

Full citation text and observation details available on the Dashboard.

footer
Global Key Solutions
Regulatory Data Transformed
Contact
New York Office:
370 Jay Street 7th Floor
Brooklyn, NY 11201
Scranton Office:
Scranton Enterprise Center, Suite 217
201 Lackawanna Avenue
Scranton, PA, 18503
🇺🇸+1 917-789-5099
🇪🇺+48 532-447-507
info@globalkeysolutions.net
Quick Links
HomePlatform OverviewMedia
KeyPedia™ Lite
Browse HubDatabase DirectoryRecordsCompaniesOfficesPeopleCareersAbout UsFounding TeamMeet Our ExpertsPartners
Legal & Ethics
Privacy PolicyTerms of ServiceOur Values & MissionCode of Ethics & AI Policy
©2026, Global Key Solutions All rights reserved.