•Encompass Group, LLC•December 22, 2009

FDA WARNING_LETTER - Encompass Group, LLC - December 22, 2009

View on Dashboard

Your cart

Your cart is empty.

Browse public document pages and click Buy this document. We'll ask for your email at checkout, no account needed up front.

Browse documents

Discuss this record with AI

ChatGPT

Claude

Perplexity

Grok

Copilot

Record Details

On December 15-22, 2009, an FDA inspection of Thermoflect's McDonough, Georgia facility, a specification developer and distributor of hypothermia prevention products (devices), revealed significant violations. The firm's devices were deemed misbranded under 21 U.S.C. 352(t)(2) due to failure to furnish required information under 21 U.S.C. 360i and 21 CFR Part 803 (Medical Device Reporting - MDR).

The primary MDR violation was the failure to develop, maintain, and implement written MDR procedures as required by 21 CFR 803.17. The existing complaint handling procedure (QSR-116, Revision 1) lacked processes for timely and effective identification, communication, and evaluation of MDR-reportable events. The firm's response, anticipating a rewritten complaint procedure by April 2010, was deemed inadequate due to lack of documented implementation evidence.

Additionally, the inspection identified nonconformances with Current Good Manufacturing Practice (CGMP) requirements of the Quality System (QS) regulation (21 CFR Part 820), including: 1. Failure to establish and maintain adequate corrective and preventive action (CAPA) procedures (21 CFR 820.100(a)), with CAPAs lacking documentation of complete implementation, investigation, and verification

Company
Encompass Group, LLC
Inspection Date
December 22, 2009
Product Type
Devices
Office
Atlanta District Office
People
  • John R. Gridley
  • Jea R. Gackowski
  • Serene N. Ackall (Compliance Officer)
Open in Dashboard

ID · 9ed024f6-9b5f-44c7-b3a9-90019215ccb8

Violation Codes10
21 U.S.C. 321(h)21 U.S.C. 352(t)(2)21 U.S.C. 360i21 CFR 803.1721 CFR 820.100(a)21 CFR 820.198(a)21 CFR 820.198(b)21 CFR 820.90(a)21 CFR 820.30(i)21 CFR 820.181(d)

Full citation text and observation details available on the Dashboard.

footer
Global Key Solutions
Regulatory Data Transformed
Contact
New York Office:
370 Jay Street 7th Floor
Brooklyn, NY 11201
Scranton Office:
Scranton Enterprise Center, Suite 217
201 Lackawanna Avenue
Scranton, PA, 18503
🇺🇸+1 917-789-5099
🇪🇺+48 532-447-507
info@globalkeysolutions.net
Quick Links
HomePlatform OverviewMedia
KeyPedia™ Lite
Browse HubDatabase DirectoryRecordsCompaniesOfficesPeopleCareersAbout UsFounding TeamMeet Our ExpertsPartners
Legal & Ethics
Privacy PolicyTerms of ServiceOur Values & MissionCode of Ethics & AI Policy
©2026, Global Key Solutions All rights reserved.