Attention www.globalkeysolutions.net is now www.keypedia.com, read the full press release here.
KeyPedia LogoKeyPedia Icon
  1. Home
  2. /
  3. Records
  4. /
  5. Warning Letter
  6. /
  7. Luminex Corporation
WARNING LETTER
•Luminex Corporation•February 14, 2020

FDA WARNING_LETTER - Luminex Corporation - February 14, 2020

View on Dashboard

Your cart

Your cart is empty.

Browse public document pages and click Buy this document. We'll ask for your email at checkout, no account needed up front.

Browse documents

Discuss this record with AI

ChatGPT

Claude

Perplexity

Grok

Copilot

Record Details

The FDA issued a Warning Letter to Luminex Corporation following inspections from February 10-14, 2020, at their Austin, TX, and Northbrook, IL facilities. The inspections revealed that Luminex's VERIGENE Processor SP System is adulterated under 21 U.S.C. § 351(h) due to non-conformity with Quality System (QS) regulation (21 CFR Part 820) and misbranded under 21 U.S.C. § 352(t)(2) for failing to report corrections or removals.

Key violations include: 1. **Failure to validate processes (21 CFR § 820.75(c)):** Luminex used heater fixtures from a new manufacturer for VERIGENE SP calibration since March 2019 without adequate validation, an approved plan, or a report, and without validating the new QC method. 2. **Inadequate CAPA procedures (21 CFR § 820.100(a)):** CAPA LMNX-CAPA-18-017, opened for false negative results with VERIGENE heat calibration fixtures, failed to document containment actions for distributed instruments serviced with inadequately validated fixtures. 3. **Inadequate servicing procedures (21 CFR § 820.200(a)):

Company
Luminex Corporation
Inspection Date
February 14, 2020
Product Type
Devices
Office
Division of Medical Device and Radiological Health Operations East
People
  • Steve Beck
  • Shari J. Shambaugh (Program Division Director)
  • Timothy T. Stenzel (Director)
Open in Dashboard

ID · 02b42ede-af22-4ce1-ba03-0e0f48ac82d3

Violation Codes10
21 U.S.C. 321(h)21 U.S.C. 351(h)21 CFR 82021 CFR 820.75(c)21 CFR 820.100(a)21 CFR 820.200(a)21 U.S.C. 352(t)(2)21 U.S.C. 360(i)21 CFR 806.1021 CFR 820.50

Full citation text and observation details available on the Dashboard.

footer
Global Key Solutions
Regulatory Data Transformed
Contact
New York Office:
370 Jay Street 7th Floor
Brooklyn, NY 11201
Scranton Office:
Scranton Enterprise Center, Suite 217
201 Lackawanna Avenue
Scranton, PA, 18503
🇺🇸+1 917-789-5099
🇪🇺+48 532-447-507
info@globalkeysolutions.net
Quick Links
HomePlatform OverviewMedia
KeyPedia™ Lite
Browse HubDatabase DirectoryRecordsCompaniesOfficesPeopleCareersAbout UsFounding TeamMeet Our ExpertsPartners
Legal & Ethics
Privacy PolicyTerms of ServiceOur Values & MissionCode of Ethics & AI Policy
©2026, Global Key Solutions All rights reserved.