FDA WARNING_LETTER - Pharmedium Services, LLC - March 22, 2013
Discuss this record with AI
Document or profile
One record shows the event. A profile shows the pattern.
Buy this document for the source file and details behind this single event.
Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.
This FDA Warning Letter, CHI-10-14, issued to PharMEDium Services, LLC, details serious deficiencies in sterile drug product manufacturing observed during inspections from February 19 to March 22, 2013, at facilities in Cleveland, MS; Edison, NJ; Memphis, TN; and Sugar Land, TX. The inspections resulted in Form FDA 483s.
Key violations include insanitary conditions and significant Current Good Manufacturing Practice (CGMP) violations. Insanitary conditions observed were operators not properly sanitizing hands, processing sterile products with exposed skin and non-sterile masks, re-using gowns, inadequate personnel monitoring, and insufficient airflow studies for ISO 5 areas. CGMP violations cited include inadequate facility design and defined areas to prevent contamination (21 CFR 211.42(b), (c)), failure to establish and follow procedures to prevent microbiological contamination (21 CFR 211.113(b)), inappropriate personnel clothing (21 CFR 211.28(a)), inadequate environmental monitoring (21 CFR 211.42(c)(10)(iv)), inadequate equipment maintenance for aseptic conditions (21 CFR 211.42(c)(10)(vi)), and insufficient stability and final product testing (21 CFR 211.166(a), 211.167(a),
ID · c50d1d61-98c1-4225-819a-b632881468cb
Full citation text and observation details available on the Dashboard.