WARNING LETTER
•Stat Medical Devices, Inc.•February 20, 2015

FDA WARNING_LETTER - Stat Medical Devices, Inc. - February 20, 2015

View on Dashboard

Your cart

Your cart is empty.

Browse public document pages and click Buy this document. We'll ask for your email at checkout, no account needed up front.

Browse documents

Discuss this record with AI

ChatGPT

Claude

Perplexity

Grok

Copilot

Record Details

On February 18-20, 2015, an FDA inspection of Stat Medical Devices, Inc. in North Miami Beach, Florida, identified that the firm, a specification developer of various blood lancets and sampling devices, was not in conformity with Quality System regulation (21 CFR Part 820). This rendered their devices adulterated under section 501(h) of the Act.

Violations included: 1. **Failure to document CAPA activities and results (21 CFR 820.100(b)):** Corrective Action Reports (CARs) for nonconformances (e.g., needle sticks, needles falling out) lacked documented root cause, impact, corrective/preventive actions, and effectiveness determination, despite being marked "Satisfactory." The firm's response was inadequate as no supporting evidence of implementation was provided. 2. **Failure to validate and monitor processes (21 CFR 820.75(a) & (b)):** The firm lacked documentation for sterilization validation and requalification assessments for their current sterilization process, making it unclear how they concluded there was "no risk" to sterilized products. 3. **Failure to establish adequate purchasing controls (21 CFR 820.50):** The firm did not implement procedures to verify vendor qualification for sterilization services, maintain quality agreements with critical sterilization vendors, or obtain written consent from foreign

Company
Stat Medical Devices, Inc.
Inspection Date
February 20, 2015
Product Type
Devices
Office
Florida District Office
Person
  • Susan M. Turcovski (Deputy Program Director)
Open in Dashboard

ID · 354c07f1-8146-4c63-b686-bdc05ff36055

Violation Codes10
21 U.S.C. 321(h)21 U.S.C. 351(h)21 CFR 82021 CFR 820.10021 CFR 820.100(b)21 CFR 820.75(a)21 CFR 820.75(b)21 CFR 820.5021 CFR 820.198(a)21 CFR 820.198(e)(3)

Full citation text and observation details available on the Dashboard.

footer
Global Key Solutions
Regulatory Data Transformed
Contact
New York Office:
370 Jay Street 7th Floor
Brooklyn, NY 11201
Scranton Office:
Scranton Enterprise Center, Suite 217
201 Lackawanna Avenue
Scranton, PA, 18503
🇺🇸+1 917-789-5099
🇪🇺+48 532-447-507
info@globalkeysolutions.net
Quick Links
HomePlatform OverviewMedia
KeyPedia™ Lite
Browse HubDatabase DirectoryRecordsCompaniesOfficesPeopleCareersAbout UsFounding TeamMeet Our ExpertsPartners
Legal & Ethics
Privacy PolicyTerms of ServiceOur Values & MissionCode of Ethics & AI Policy
©2026, Global Key Solutions All rights reserved.