On November 18, 2013, the FDA issued a Warning Letter to Synecco Ltd. following an inspection from July 8-10, 2013, in Ningbo, China. The firm, a contract manufacturer and sterilizer of medical devices like feeding tubes and liquid medication dispensers for U.S. distribution, was found to have adulterated devices under 21 U.S.C. § 351(h) due to non-conformity with Quality System (QS) regulation (21 CFR Part 820).

Key violations included: 1. **Failure to establish and maintain CAPA procedures (21 CFR 820.100(a)(3)):** A corrective action for a syringe defect lacked identified actions to prevent recurrence and an appropriate sampling plan for final inspection. The firm's response was inadequate as the sampling plan was not addressed, and corrective actions were incomplete. 2. **Failure to maintain complaint investigation records (21 CFR 820.198(e)):** Complaints from May 2012 to June 2013 lacked crucial information such as receipt date, source, complainant feedback, root cause, and disposition date. The adequacy of the firm's response could not be determined as corrective actions were incomplete. 3. **Failure to validate processes (21 CFR 820.75(a)):

Company
SYNECCO LTD.
Inspection Date
July 10, 2013
Product Type
Devices
Office
Center for Devices and Radiological Health
People
  • Tony Doherty
  • Steven D. Silverman (President)
Open in Dashboard

ID · e65c784f-4a78-4577-81e0-567a7d23da2c

Violation Codes9
21 U.S.C. 321(h)21 U.S.C. 351(h)21 CFR 82021 CFR 820.100(a)(3)21 CFR 820.198(b)21 CFR 820.198(e)21 CFR 820.75(a)21 CFR 820.2221 CFR 820.60

Full citation text and observation details available on the Dashboard.

footer
Global Key Solutions
Regulatory Data Transformed
Contact
New York Office:
370 Jay Street 7th Floor
Brooklyn, NY 11201
Scranton Office:
Scranton Enterprise Center, Suite 217
201 Lackawanna Avenue
Scranton, PA, 18503
🇺🇸+1 917-789-5099
🇪🇺+48 532-447-507
info@globalkeysolutions.net
Quick Links
HomePlatform OverviewMedia
KeyPedia™ Lite
Browse HubDatabase DirectoryRecordsCompaniesOfficesPeopleCareersAbout UsFounding TeamMeet Our ExpertsPartners
Legal & Ethics
Privacy PolicyTerms of ServiceOur Values & MissionCode of Ethics & AI Policy
©2026, Global Key Solutions All rights reserved.