FDA 483 - Rancho Park Compounding Pharmacy - May 07, 2019
Discuss this record with AI
Document or profile
One record shows the event. A profile shows the pattern.
Buy this document for the source file and details behind this single event.
Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.
An FDA Form 483 was issued following an inspection of a sterile compounding lab, revealing multiple deficiencies in facility design, operations, and aseptic processing.
Observations included visibly dirty equipment and surfaces in ISO 5 Laminar Flow Workstations (LAFWs), with yellowish-brown stains and spots on stainless steel surfaces, curved metal hooks, cap screws, and HEPA filter covers. Non-microbial contamination was noted in ISO 7 buffer and anterooms, including chipped ceiling material, discolored bolt screws, and dirty HEPA filter covers.
Personnel were observed blocking first-pass air during aseptic manipulations, specifically when capping sterile dropper tips for Dexamethasone Ophthalmic Soln. Non-sterile wipes were used with disinfecting agents in ISO 5 LAFWs, and materials were not properly disinfected before entering aseptic processing areas.
The facility's design included dust-collecting overhangs like wall cable raceways in ISO 7 areas that were difficult to clean. Gowning procedures were improper, with gowns touching the floor and wet spillage. Unsealed and loose ceiling tiles, including a cracked light cover and unsealed light fixture frame, were found in the ISO 7 buffer room. The gowning room's layout in the ISO 7 anteroom was deemed to permit poor flow of personnel and materials, leading to potential contamination of gowning apparel.