FDA 483 - Age Management Institute Santa Barbara - April 12, 2021
Discuss this record with AI
Document or profile
One record shows the event. A profile shows the pattern.
Buy this document for the source file and details behind this single event.
Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.
The FDA Form 483 documents observations from an inspection of a facility producing purportedly sterile drug products for intravenous (IV) infusion and IV syringes based on doctor's prescriptions.
Key observations include: 1. **Lack of HEPA Filtration:** No HEPA filter was present over the area where sterile product was exposed, specifically in the (b) (4) (b) (4) hood or the IV storage and mixing room. A (b) (4) was used instead of a HEPA filter in the hood, resulting in sterile drug products being produced in an unclassified area. Between 1/13/2021 and 2/25/2021, (b) (4) purportedly sterile drug products were produced under these conditions. 2. **Non-Microbial Contamination:** The production area, particularly the IV storage and mixing room, exhibited significant non-microbial contamination. This included: * Use of an expired (b) (4) (dated 08/28/2008) in the (b) (4) hood, with a dirty back. * A (b) (4) refrigerator storing sterile vials had water drips on caps, water in trays, and ice/frost buildup. * The (b) (4) hood's working surface had unknown stains and peeling paint on non-working surfaces.
ID · 3cd0dac2-f70d-4e64-ac25-c70638bb3560
Full citation text and observation details available on the Dashboard.