FDA 483 - ApotheCure Inc - August 13, 2007
Discuss this record with AI
Document or profile
One record shows the event. A profile shows the pattern.
Buy this document for the source file and details behind this single event.
Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.
The FDA Form 483 details numerous violations at a drug compounding facility, ApotheCure Inc., related to sterile injectable drug products and overall quality control.
**Facility and Operations:** The firm compounds sterile injectables like DMPS, EDTA Disodium, and Prolotherapy AQ 1%, along with capsules and creams. The Ante Room and Laminar Airflow Workbench (LAFW) are critical areas for sterile compounding.
**Violations and Observations:**
* **Sterility Testing & Pyrogen Testing:** Only a limited sample from sterile injectable batches is sent for sterility analysis, regardless of batch size. No pyrogen testing is conducted. * **Sterilization Process Validation:** * No evaluation of the Ante Room or LAFW for airborne microorganisms (e.g., weekly). * Sterilization processes for glass vials, stoppers, scoops, and finished injectables (e.g., DHEA, Hyaluronic Acid) lack documented validation. * Sterile filling processes for all injectable products (e.g., Calcium-Disodium EDTA, DMPS) lack documented effectiveness. * Cleaning regimens for equipment and LAFW lack documented effectiveness. * **Microbiological Contamination Prevention:** * Procedures for controlling contamination in the Ante Room are inadequate. * Employees gown up in an uncontrolled environment outside the Ante Room. * An insect trap and a portable radio were observed in
ID · 5177f5f7-e0b6-4268-8e72-f742d32334c2
Full citation text and observation details available on the Dashboard.