FDA 483 - Avella of Deer Valley dba Avella Specialty Pharmacy - February 25, 2013
Discuss this record with AI
Document or profile
One record shows the event. A profile shows the pattern.
Buy this document for the source file and details behind this single event.
Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.
The FDA Form 483 details significant deficiencies at a sterile drug product manufacturing facility.
**Gowning and Personnel:** - Technicians wore non-sterile gowns with exposed skin (eyes, neck) in ISO 7 cleanrooms, violating SOP 03 S-32. - Sterile gloves were donned in the ISO 7 ante-room, then used to wipe down ISO 5 Biosafety cabinets before aseptic processing, risking contamination. - Operators' forearms, covered by non-sterile gowning, entered ISO 5 environments. - Personnel monitoring (glove/fingertip sampling) was infrequent, not conducted after every lot.
**Environmental Monitoring:** - Inadequate routine viable and non-viable particulate air monitoring in ISO 5 and ISO 7 environments during aseptic processing. Monitoring was primarily static or by external contractors during certification. - No monitoring of cleanroom pressure differentials during aseptic processing; only external contractor monitoring at static conditions. - Insufficient frequency and rotation of surface environmental monitoring in ISO 5 and ISO 7 cleanrooms, not sampling every surface or after each lot.
**Sterilization and Water Systems:** - No written SOP for the in-house sterilization equipment (e.g., for vials); verbal on-the-job training only. - Lack of routine monitoring (e.g., temperature display/recording, data charts) for each sterilization run, only periodic biological indicator processing. - No firm
- Inspection Date
- February 25, 2013
- Product Type
- Drugs
ID · 85506ea4-1131-4db7-956b-8553950e72f5
Full citation text and observation details available on the Dashboard.