FDA 483 - MedisourceRx - October 22, 2020
Discuss this record with AI
Document or profile
One record shows the event. A profile shows the pattern.
Buy this document for the source file and details behind this single event.
Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.
The FDA Form 483 details multiple deficiencies observed during an inspection.
**Facility and Operation Details:** The document pertains to a drug product manufacturing facility producing Glutathione and Aviptadil, including both vial and syringe presentations. Operations involve 100% visual inspection, aseptic processing, media fills, and compounding.
**Violations and Observations:**
* **Inadequate Discrepancy Review (Repeat Observation):** Major defects from 100% visual inspection were not thoroughly investigated. * Unknown particles in multiple Glutathione and Aviptadil drug product lots were not identified. * Investigations for media fill lots exceeding particulate action limits (e.g., Syringe lots (b)(4) and (b)(4)) were inadequate, with conclusions (e.g., aggregate from (b)(4) media) unconfirmed. * No effort was made to identify particles in media fill vial product lots (e.g., lots (b)(4), (b)(4), (b)(4), (b)(4)). * The (b)(4)% alert/action limits for major defects in visual inspection and discontinuation of (b)(4) inspection in drug product release were not justified.
* **Inadequate Aseptic and Sterilization Process Validation:** * Not all media fill units from Nov 2019 (syringes) and Feb 202
ID · a1e1ffa0-3bb0-4b18-a86d-b3dda15cef25
Full citation text and observation details available on the Dashboard.