FDA 483 - Pharmedium Services, LLC - September 24, 2015
Discuss this record with AI
Document or profile
One record shows the event. A profile shows the pattern.
Buy this document for the source file and details behind this single event.
Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.
The FDA Form 483 details multiple deficiencies at a drug product manufacturing facility.
**Facility and Operations:** The firm produces sterile drug products, including Norepinephrine, Magnesium Sulfate, Vancomycin HCl, and Oxytocin.
**Violations and Observations:** 1. **Aseptic Technique Failure:** On 08/24/2015, a pharmacist placed their head inside an ISO 5 Laminar Air Flow hood while collecting Norepinephrine 4mg 250 ml, 5% Dextrose Injection, USP (Lot 15236112S), violating SOP CPS-305, Version 13.0, which prohibits leaning into or against the hood. 2. **Deficient Sterility and Endotoxin Testing:** The firm failed to perform sterility and endotoxin testing on each lot of sterile drug product prior to release and distribution, only testing a fraction of products. Examples include Norepinephrine (Lot 15236112S), Magnesium Sulfate (Lot 15237091S), Vancomycin HCl (Lot 15238397S), and Oxytocin (Lot 15237111S), all shipped prior to sterility testing. 3. **Deficient Potency Testing:** Potency testing was not performed on each lot of drug product prior to release and distribution, only on a fraction
ID · 0e5b3c76-f017-4c17-a923-5d6931489802