FDA 483 - Teva Parenteral Medicines, Inc. - July 24, 2009
Discuss this record with AI
Document or profile
One record shows the event. A profile shows the pattern.
Buy this document for the source file and details behind this single event.
Choose full profile access to connect related records, sites, people, citations, and enforcement history in one view.
The FDA Form 483 details numerous deficiencies at a drug manufacturing facility. The quality control unit lacks responsibility for approving/rejecting procedures impacting drug product identity, strength, quality, and purity. The company failed to submit post-approval or change-being-effected changes for a BI challenge in steam sterilization.
Several issues relate to product testing and release: - Out-of-trend bacterial endotoxin results were observed in finished product lots (e.g., MIR 09-003, MIR 09-015). - Drug product release does not include appropriate laboratory determination of conformance to final specifications. - There is no assurance that Propofol Injectable Emulsion 1% is free of bacterial endotoxin. - In-process materials are not tested for quality/purity or approved/rejected by QC. - Bioburden levels are sampled from non-sterile bulk solution and end-of-run samples (aseptically filled vials prior to sterilization). - Acceptance criteria for QC sampling/testing are inadequate to assure batches meet statistical quality control criteria.
Investigation failures include: - Unexplained discrepancies are not thoroughly reviewed, even for distributed batches. - Investigations do not extend to other batches or drug products potentially affected. - No consideration was given to other Propofol products manufactured on the same filling line.
Quality system and documentation issues: - QC unit responsibilities and procedures are not in writing.